Faber Perla Plan The Installation, Rangehood Assembly, Calculate The Ductrun Length

Models: Perla

1 12
Download 12 pages 28 Kb
Page 5
Image 5
PLAN THE INSTALLATION

TOOLS NEEDED FOR INSTALLATION

Saber Saw or Jig Saw

Drill

1 1/4" Wood Drill Bit

Pliers

Phillips Screwdriver

Flat Blade Screwdriver

Wire Stripper or Utility Knife

Metal Snips

Measuring Tape or Ruler

Level

Pencil

Caulking Gun

Duct Tape

PARTS SUPPLIED FOR INSTALLATION

1 Hardware Package

1 Literature Package

PARTS NEEDED FOR INSTALLATION

2 Conduit Connectors

Power Supply Cable

1 Wall or Roof Cap

All Metal Ductwork

PLAN THE INSTALLATION

This rangehood can be installed as either ducted or ductless. In a ducted application, this rangehood can be vented through the wall or ceiling. To vent through a wall, a 90° elbow is used. When installed ductless, the rangehood vents out of grates on the sides of the chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.

WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILLBE USEDAND CAREFULLY CALCULATE ALL MEASUREMENTS.

PLAN THE INSTALLATION

The Perla chimneys are adjustable and designed to meet varying ceiling heights as indicated in FIGURE 2. The chimneys can be adjusted for ceil- ings between 7' 8 1/2" and 9' 9 1/2" depending on the distance between the bottom of the hood and the cooktop (distance x in FIGURE 2).

FIGURE 2

1” min

upper

20” max

chimney

22”

 

lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chimney

 

 

min & max ceiling height examples

 

 

 

 

 

x = 24"

x = 26"

x = 28"

x = 30"

 

 

 

 

 

 

 

 

min

min

min

min

 

 

 

9 1/2”

 

canopy

7' 8 1/2"

7' 10 1/2"

8' 1/2"

8' 2 1/2"

 

 

 

 

 

 

max

max

max

max

 

 

 

9' 3 1/2"

9' 5 1/2"

9' 7 1/2"

9' 9 1/2"

 

 

 

 

193/8”

x=distancefromhoodtocooktop x (varies depending on installation) min - 24”, suggested max - 30”

also consult cooktop

manufacturer's recommendation

36”

cabinet base

 

 

RANGEHOOD ASSEMBLY

For shorter ceilings, have the chimney cover(s) cut at a sheet metal shop. For higher ceiling installations, the High Ceiling Chimney Kit includes a new 40” upper chimney which would replace the 20” upper chimney that came with the hood. (see OPTIONAL ACCESSORIES page 4)

CALCULATE THE DUCTRUN LENGTH

Theductrunshouldnotexceed35equivalent feet if ducted with the required minimum of 6" round ductwork. Calculate the length of the ductwork by adding the equivalent feet in FIGURE3foreachpieceofductinthesystem. An example is given in FIGURE 4.

For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbowrightaway,doitasfarawayfromthe hood's exhaust opening as possible.

45˚ Elbow

3.0 feet

90˚ Elbow

5.0 feet

90˚ Flat Elbow

12.0 feet

Wall Cap

0.0 feet

FIGURE 3

 

 

 

 

 

 

9 Feet Straight Duct

9.0 feet

2 - 90˚ Elbows

10.0 feet

Wall Cap

0.0 feet

Total System

 

19.0 feet

 

FIGURE 4

FIGURE 1

!WARNING

PERSONAL INJURY HAZARD

Because of the weight and size of the rangehood canopy, two or more people are needed to move and safely install the rangehood canopy. Failure to properly lift rangehood could result in damage to the product or personal injury.

Version 9/05 - Page 5

Page 5
Image 5
Faber Perla installation instructions Plan The Installation, Rangehood Assembly, Calculate The Ductrun Length