VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. If it is used, each foot of flexible ductwork used is equivalent to two feet of straight metal ductwork when calculating the ductrun length. Thus, a flexible elbow equals two standard elbows.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO

TO PAGE 5.

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

!WARNING

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is not recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

For residential use only.

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever nec- essary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:InstallationWorkAndElectricalWiringMust Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire ProtectionAssociation (NFPA), and theAmerican Society for Heating, Refrigeration andAir Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not dam- age electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

!WARNING

Electrical ground is required on this rangehood.

If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

Failure to follow electrical requirements may result in a fire.

Version 9/05 - Page 2

Page 2
Image 2
Faber Perla Venting Requirements, For More Specific Ductwork INFORMATION, GO, Electrical Requirements

Perla specifications

Faber Perla is a high-performance kitchen hood designed to enhance the cooking experience while maintaining an elegant aesthetic. This innovative appliance merges functionality with style, making it a popular choice among modern homeowners.

One of the standout features of the Faber Perla is its powerful extraction system. Equipped with advanced motor technology, this kitchen hood offers exceptional suction power, effectively eliminating smoke, odors, and steam generated during cooking. As a result, the air quality in the kitchen remains fresh, allowing culinary enthusiasts to focus on their craft without distraction.

The Faber Perla is designed with versatility in mind. It comes in various sizes and configurations to suit different kitchen layouts and styles. Whether you have a compact apartment kitchen or a spacious gourmet setup, there is a model that fits seamlessly into your space. The sleek, minimalist design complements any décor, making it a stylish addition to any home.

Another notable feature of the Faber Perla is its user-friendly interface. The intuitive controls allow for easy adjustment of fan speeds and lighting, ensuring that users can manage their cooking environment effortlessly. Many models are equipped with LED lights that provide ample illumination over the cooking surface, making meal prep safer and more convenient.

The technology behind the Faber Perla is impressive as well. Many units utilize advanced filtration systems, including aluminum mesh filters and optional charcoal filters. These filters efficiently capture grease and particulates, ensuring that the air extracted is clean. Moreover, the filters are washable and reusable, promoting easier maintenance and longer product life.

In addition to its performance and technology, the Faber Perla is engineered with noise reduction in mind. Many models feature sound-absorbing technology that minimizes operational noise, creating a more pleasant cooking environment. This is particularly beneficial for open-concept living spaces, where kitchen sounds can easily carry into adjoining areas.

Overall, the Faber Perla is a remarkable blend of efficiency, style, and advanced technology. With its powerful extraction capabilities, customizable features, and elegant design, it stands as a superior choice for anyone looking to elevate their kitchen experience while ensuring a clean and comfortable cooking atmosphere. Whether you're a passionate home chef or someone simple enjoying meal preparation, the Faber Perla offers both practicality and sophistication in one impressive package.