EN

 

6 / USER-MAINTENANCE INSTRUCTIONS

 

 

 

• DIRECT EVACUATION OF WATER CONDENSER

To avoid having to empty the collection tank every time you use the appliance, you have a kit (*) for removing the water from the condenser directly into the drain (hose and deflector). To fit this :

— Take off the existing pipe and push it inside the appliance (Fig. 13).

— Clip the deflector with the top of the pump (Fig. 14).

— Connect the hose from the kit to the end connector

EN 6 / USER-MAINTENANCE INSTRUCTIONS

• CLEANING THE CONDENSER

Important :

 

The condenser must be cleaned twice a

 

month.

 

Important :

 

Unplug the power cable from the socket

Fig. 18

before cleaning the condenser.

— Open the grill at the front of the appliance.

 

on the appliance (Fig. 15)

Fig. 13

— Release the condenser (Fig.18).

— Remove it carefully (Fig.19).

You can connect the other end of the hose either :

-To a ventilated trap (Fig. 16).

-Or a sink trap (Fig. 17).

When connecting to a trap, you must remove the fil- ler plug. Then press home the rubber tip. If neces- sary, add a clamp connection (Fig. 17).

Fig. 14

— Remove any fluff from the condenser.

 

 

 

— Clean it with water only under the tap (Fig.20).

 

 

 

— After cleaning, ensure that none of the tubes are

Fig. 19

“blocked” and that the fins are clean.

— Rub it superficially.

 

 

 

 

 

 

Re-insert the condenser and lock it in place. Close

 

 

 

the grill.

 

 

 

 

 

 

 

 

 

 

Important :

The deflector must be positioned before the drain hose connection to avoid any water splashes when taking off the hose.

Fig. 20

Important :

When refitting the condenser, ensure that it is pushed in firmly right to the back of its hou- sing when locking it in

Remarks :

(*)This kit is provided with the appliance or is available near your After-sales service under the ref. 57X3184 (according to model).

Hose

Deflector

Insert

Fig. 15

90 cm maxi

Fig. 16

• CLEANING THE APPLIANCE

Advice :

To clean the control panel, the access to the drum and the casing, use only a sponge or a damp cloth and some soapy water.

Ensure that there is no fluff accumulating round the dryer.

Clean the door seal with a damp cloth.

Clean the filter housing with your vacuum cleaner once a year.

You should not use, under any circumstances (Fig

21):

Fig. 21

Fig. 17

18

Abrasive powders

Metal or plastic sponges

Alcohol-based products (alcohol, thinners, etc.)

19

Page 10
Image 10
Fagor America SFA-8CELX Direct Evacuation of Water Condenser, Cleaning the Condenser, Cleaning the Appliance