Fantom Vacuum AP500H Maintenance Instructions, Operating Instructions, Cleaning the Air Purifier

Models: AP500H

1 8
Download 8 pages 46.76 Kb
Page 7
Image 7
MAINTENANCE INSTRUCTIONS

MAINTENANCE INSTRUCTIONS

OPERATING INSTRUCTIONS

Cleaning the Air Purifier

Disconnect the unit from the outlet before performing maintenance or troubleshooting.

It is recommended that you regularly clean the air intake grill and pre-filter between filter changes. Every 30 days is the recommended schedule.

1.Lay the unit down with face upwards.

2.Grasp both corners of the bottom of the air intake grill and pull upwards. (Fig. 8)

Fig. 8

3.Lift air intake grill gently towards top of unit, to remove.

4.To remove the HEPA filter, pull up on the tags on either side of the filter and lift upwards. (Fig. 9)

Tags

Fig. 9

5.To clean the pre-filter, pull the pre- filter up to remove it from the HEPA filter. (Fig. 10)

8.To replace the air intake grill, first attach the top of the grill and then snap in the lower part of the grill.

Replacing the HEPA Filter

The HEPA filter should last approximately six (6) to nine (9) months depending on usage and household environment. The change filter indicator will illuminate when the filter requires replacing. Disconnect the unit from the power source before performing any maintenance or troubleshooting. WARNING: Do not attempt to wash or vacuum the HEPA filter as this will cause damage to the filter.

1.Lay the unit down with face upwards.

2.Grasp both corners of bottom of the air intake grill and pull upwards. (Fig. 8)

3.To remove the HEPA filter, pull up on the tags on either side of the filter and lift upwards. (Fig. 9)

4.Remove the new HEPA filter from the bag.

5.There is a sticker located on the base and top of the HEPA filter, fill in the date that this filter was installed into the unit. This helps you keep track of when a new filter will be needed.

6.Insert the new HEPA filter into the air purifier with the arrow pointing down. (Fig. 13)

Before Using the Air Purifier

Remove all parts from packaging. Insert 2 AAA batteries into the remote control. Before use verify that the HEPA filter is in place:

1.Lay the unit down with face upwards.

2.Grasp both corners of the bottom of the air intake grill and pull upwards. (Fig. 1)

Fig. 1

3.To replace the air intake grill- insert the top of the air intake grill first and then snap in the lower part of the grill.

4.Plug the unit into an electric outlet, the unit will be ready to run.

5.Press the “On/Off” button on the display panel to turn the unit “On”.

Description of the Display Panel

Display Panel

Using the Air Purifier

1.Plug the unit into an electric outlet, the unit will be ready to run.

2.Press the “On/Off” button on the display panel to turn the unit “On”. Repress the button to turn the unit “Off”.

Fan Speed

NOTE: There will be approximately a one (1) second delay between pressing the fan speed button and the unit changing speed.

1.When the unit is turned on, the fan will automatically start at medium speed for about 3 seconds and then default to low speed. The fan speed is indicated on the control panel.

2.To change the fan speed, press the fan speed control button on the front of the unit. Each time it is depressed the fan speed changes ranging from quiet to auto. (Fig. 2)

Fan Settings:

Fig. 2

 

1= Quiet

2= Low

3= Medium

4= High Auto

3.If you select the auto fan speed, the dust and odor sensors will detect the air quality in the room and will

automatically adjust the fan speed. NOTE: When the fan speed is in the “AUTO” mode, AUTO will appear at the

HEPA

Filter Frame

Fig. 10

Fig. 13

7. To replace the air intake grill, first

attach the top of the grill and then

snap in the lower part of the grill.

 

Control

Display Panel

Buttons

1.

Fan Speed Indicator

2.

Infra-Red Receptor

3.

Odor Detected in Air Indicator

4.

Dust Detected in Air Indicator

top right hand corner of the display panel. The fan speed will appear after the sensors select the required fan speed for the most efficient cleaning.

6.Run under tap water until water runs clear. Allow to air dry for 24 hrs before replacing onto the HEPA filter frame. (Fig. 11)

7.To clean the air intake grill, you may use a vacuum with a crevice tool to get trapped dust out from between the gaps.

Then clean with a

damp cloth to remove any extra dirt and dust. (Fig. 12)

Fig. 11

Fig. 12

8

8. To reset the clean filter indicator

plug the unit in, turn the unit “On”,

then press and hold the timer button

until the clean filter indicator turns

off.

5.

Timer Display

6.

Change Filter Indicator

Control Buttons

7.Fan Speed Control Button

8.Neutralize “On/Off” Indicator

9.Neutralize “On/Off” Control Button

10.“On/Off” Power Button

11.Ionizer Control Button

12.Ionizer “On/Off” Indicator

13.Timer Control Button

5

Page 7
Image 7
Fantom Vacuum AP500H Maintenance Instructions, Operating Instructions, Cleaning the Air Purifier, Using the Air Purifier