REPLACING THE FLAT BELT

REPLACEMENT INSTRUCTIONS

Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the power cord from the wall outlet before replacing any of the parts below.

REPLACING THE FLAT BELT

Remove the bottom plate.

1 (refer to page 15)

Lift out the agitator assembly, and then remove the flat belt from the motor shaft and

2 the agitator pulley.

Manual backgroundManual backgroundManual background Motor Shaft

Manual background Flat Belt

3 Place a new flat belt onto the motor shaft and pulley.

Manual backgroundManual background Motor Shaft

Manual background Flat Belt

Flat Belt

Pulley

Place the agitator assembly into the grooves in the nozzle head, making sure that the new

4 flat belt slides securely into the guide.

Bearing Holder

Groove

Nozzle Head

Reattach the bottom plate

5 (refer to page 15)

Caution:

Install the flat belt so that it has no twists in it, and so that all components turn smoothly.