Product Specifications

PHYSICAL DATA

MODEL NUMBER AFPB24A1 AFPB24B1 AFPB36A1 AFPC48A1 AFPC48B1 AFPC60A1 AZFPC60B1
ELECTRIC DATA (208/230 VOLT, SINGLE PHASE, 60 Hz)
VOLTAGE 208 /230 208 /230 208 /230 208 / 230 208 / 230 208 /230 208 / 230
MINIMUM CIRCUIT AMPACITY MCA(AMPS) 15 15 15 15 15 15 15
MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP(AMPS) 15 15 15 15 15 15 15
BLOWER
FAN MOTOR TYPE PSC
HP1/6 1/6 1/3 1/2 1/2 3/4 3/4
BLOWER DIMENSIONS 9x7 9x7 9x10 9x 8 9x 8 10 x 9 10 x 9
COIL DATA
TYPE A-COIL
COIL FACE AREA (ft2)4 4 4 5.8 5.8 5.8 5.8
O.D.
3/8"
ROWS / FPI 2- 14 3-14 3 - 14 3-12 4 - 12 3 - 12 4 - 12
REFRIGERANT LINE CONNECTION
LIQUID LINE CONNECTION SIZE (IN. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
SUCTION LINE CONNECTION SIZE (IN. OD) 3/4 7/8 7/8 7/8 7/8 7/8 7/8
FILTER DATA
RECOMMENDED FILTER SIZE (H X W X D) (in)
(FILTER NOT SUPPLIED) 16 x 20 x 1 16 x 20 x 1 16 x 20 x 1 20 x 25 x 1 20 x 25 x 1 20 x 25 x 1 20 x 25 x 1
2
Specifications subject to change without notice.
Clearance to Combustible Material

Clearances from the air handler to the combustibles are zero inches from all sides,top, and bottom; one inch from discharge

air plenum;and the duct within 36 inches of the plenum.