Federal Security Camera 300GC Iv. Testing/Operating, Safety Message To Operators, V.Maintenance

Models: 302GC 300GC 300GCX

1 28
Download 28 pages 62.62 Kb
Page 7
Image 7
IV. TESTING/OPERATING.

Property damage, serious injury, or death could occur if the housing is not closed properly. To reduce possibility of explosion, the housing cover must be kept tight while circuits are energized.

IV. TESTING/OPERATING.

These devices are capable of producing sounds loud enough to cause hear‑ ing damage. Adequate hearing protection should be worn if standing within close proximity to device while testing. Recommendations in the OSHA Sound Level Standard (29 CFR 1910F) should not be exceeded.

A.After installation is complete, be sure to test the system to verify that each amplified speaker operates satisfactorily. If it is found that the unit is too loud for its location, an internal volume control can be adjusted. Remove the housing cover. Using a slotted screwdriver with a 1/8" blade, gently turn control to desired loudness. See figure

2.Reinstall the housing cover.

B.After completion of initial system test, establish a program for periodic test‑ ing of this device.

C.Provide a copy of these instructions for the Safety Engineer, system operator(s) and maintenance personnel.

 SAFETY MESSAGE TO OPERATORS SAFETY MESSAGE TO OPERATORS

Even if your warning system is operating properly, it may not be completely effective. People may not hear or heed your warning signal. You must recog‑ nize this fact and ensure that your warning signal achieves its intended effect through proper test/training sequences within your specific application(s).

- EXPLOSION HAZARDV.MAINTENANCE. SAFETY MESSAGE TO MAINTENANCE PERSONNEL- EXPLOSION HAZARD

Substitution of components may impair suitability for Class I, Division 2, and Class I, Zone 2.

V.MAINTENANCE.

Manual background SAFETY MESSAGE TO MAINTENANCE PERSONNEL

Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or others.

Read and understand all instructions before performing maintenance on this unit.

To reduce the risk of electrical shock or ignition of hazardous atmo‑ spheres, do not perform maintenance or service on this unit when circuits are energized.

-6-

Page 7
Image 7
Federal Security Camera 300GCX Iv. Testing/Operating, Safety Message To Operators, Explosion Hazard, V.Maintenance