SIZING AND SELECTING UNITS
See chart below:
Square Footage | Volts | Watts | Amps | Hz | |
(For ducts at least 16" wide) | |||||
Up to 2000 | 1 | 24 | 23 | 1.3 | 60 |
4000 | 2 | 24 | 46 | 2.6 | 60 |
Notes:
•For applications with multiple systems, we recommend one unit per system.
•For larger applications, multiple units are recommended.
Contact technical support at
•Each unit will require its own transformer.
Figure 1 |
INSTALLATION |
| ||
1. | Locate a suitable location for the unit downstream from the 'A' coil in |
| |
| the supply plenum or in the return plenum; preferably downstream from |
| |
| the air filter. For optimum "cleaning" effect on the 'A' coil, mount the |
| |
| unit in the supply plenum as close as possible to the 'A' coil. |
| |
| (See Figure 1) |
| |
CAUTION: Investigate and determine the location of the A coil prior to |
| ||
drilling holes in duct for mounting unit. |
| ||
NOTE: For duct board installation, refer to enclosed bagged assembly |
| ||
containing mounting plate and instructions. | Figure 2 | ||
2. | Apply supplied mounting template to air duct in either | ||
| |||
| a vertical or horizontal position. (See Figure 2) Leave |
| |
| template mounted to duct for future reference. |
| |
3. | Drill 1⁄8" diameter mounting holes at positions indicated |
| |
| on template. (See Figure 3) |
| |
4. | Cut out the large opening |
| |
| (See Figure 3) |
| |
5. | Using a 1⁄4" to 1⁄2" drill bit, drill a viewport hole as |
| |
| indicated on the template. (Figure 3) |
| |
6. | Optional Light Shield: The light shield may be mounted |
| |
| at virtually any angle. However, when deciding on a |
| |
| suitable location, the mounting screw head can not be in |
| |
| the shaded area of template. (See Figure 4 to view areas |
| |
| to avoid.) | Figure 3 | |
|
|
Figure 4
Head of mounting screw CANNOT be
located in shaded area.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the
page 3