2. Determine the type of duct you have.

(For flex duct applications, refer to Figure 21 on page 8)

IF YOU HAVE METAL DUCT:

a. Apply supplied wet and stick mounting template to air duct in either a vertical or horizontal position as shown in Figure 2.

b. Drill 1/8” diameter mounting holes at positions indicated on template.

c. Cut out rectangular hole on template using a pair of tin snips or jigsaw. (See Figure 2) Remove template.

IF YOU HAVE DUCT BOARD:

a. Mount the supplied metal mounting plate onto the duct with

Figure 2

duct tape in either a vertical or horizontal position as shown

in Figure 2. (See Figure 3)

 

b.Bend tabs outward as shown in figure 4.

c.Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 5)

d.Remove the cut piece of duct. (See Figure 7)

e.Bend both tabs down and through duct at first bend point. (See Figures 8 &9)

f.Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 10 & 11

g.Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See Figure 12)

Figure 3

Figure 4

Figure 5

Figure 7

Figure 9

Figure 10

Figure 11

Figure 12

Figure 8

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.