FieldServer instruction manual FS-8700-103ATMITGMSerial Manual Message, Fyi

Models: FS-8700-103

1 28
Download 28 pages 23.4 Kb
Page 23
Image 23

FS-8700-103_ATMI_TGM_Serial Manual

Page 23 of 28

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

 

 

 

Notes and Corrective Action

 

 

 

 

TGM: #10 Err. No space. Reject

 

An attempt has been made to extend the gas name table.

 

 

 

Gas

Name=<%s>

Index

 

There is insufficient space to add more names. Remove this

 

 

 

Value=%d

 

 

 

 

entry from the configuration CSV file3.

 

 

 

 

 

 

 

 

 

 

This message may be ignored. It is printed to alert you to

 

 

 

TGM: #11 FYI. User added Gas

 

the fact that the driver has updated the Gas Name table by

 

 

 

Name=<%s> Index Value=%d

 

adding a new gas name and index value. Ensure that index

 

 

 

 

 

 

 

 

 

values are unique.

 

 

 

 

TGM: #12 FYI. Duplicate Gas

 

This message may be ignored. It is printed to alert you to

 

 

 

Units=<%s>.

Value

has

been

 

the fact that the driver has updated the Gas Engineering

 

 

 

updated from=%d to=%d

 

 

Unit table so that default values have been modified.

 

 

 

TGM: #13 Err. No space. Reject

 

An attempt has been made to extend the Fas Engineering

 

 

 

Gas

Units=<%s>

Index

 

Units table. There is insufficient space to add more names.

 

 

 

Value=%d

 

 

 

 

Remove this entry from the configuration CSV file.3

 

 

 

 

 

 

 

 

 

This message may be ignored. It is printed to alert you to

 

 

 

TGM: #14 FYI. User added Gas

 

the fact that the driver has updated the Gas Engineering

 

 

 

Units=<%s> Index Value=%d

 

Units Table by adding a new gas name and index value.

 

 

 

 

 

 

 

 

 

Ensure that index values are unique.

 

 

 

 

TGM:

#15

FYI.

Duplicate

 

This message may be ignored. It is printed to alert you to

 

 

 

Malfunction=<%s>.

Index

Val

 

the fact that the driver has updated the Malfunction Table so

 

 

 

has been

updated

from=%d

 

that default values have been modified.

Ensure that the

 

 

 

to=%d

 

 

 

 

 

index value is less than 100.

 

 

 

 

TGM: #16 Err. No space. Reject

 

An attempt has been made to extend the Malfunction Table.

 

 

 

Malfunction=<%s>

 

Index

 

There is insufficient space to add more names. Remove this

 

 

 

Val=%d

 

 

 

 

 

entry from the configuration CSV file.3

 

 

 

 

TGM: #17 FYI. User added

 

This message may be ignored. It is printed to alert you to

 

 

 

 

the fact that the driver has updated the Malfunction Table by

 

 

 

Malfunction=<%s>

 

Index

 

adding a new gas name and index value. Ensure that index

 

 

 

Val=%d

 

 

 

 

 

values are unique and that the index value is less than 100.

 

 

 

 

 

 

 

 

 

 

 

 

TGM:

#18

FYI.

Duplicate

 

This message may be ignored. It is printed to alert you to

 

 

 

Normal Event=<%s>.

 

 

 

the fact that the driver has updated the ‘Return to Normal’

 

 

 

Index Val has been updated

 

Table so that default values have been modified. Ensure

 

 

 

from=%d to=%d

 

 

 

that the index value is less than 100.

 

 

 

 

TGM: #19 Err. No space. Reject

 

An attempt has been made to extend the ‘Return to Normal’

 

 

 

Normal

Event=<%s>

Index

 

Table. There is insufficient space to add more names.

 

 

 

Val=%d

 

 

 

 

 

Remove this entry from the configuration CSV file.3

 

 

 

 

 

 

 

 

 

This message may be ignored. It is printed to alert you to

 

 

 

TGM: #20 FYI. User added

 

the fact that the driver has updated the ‘Return to Normal’

 

 

 

Normal

Event=<%s>

Index

 

Table by adding a new gas name and index value. Ensure

 

 

 

Val=%d

 

 

 

 

 

that index values are unique and that the index value is less

 

 

 

 

 

 

 

 

 

than 100.

 

 

3 Modify the configuration CSV file. Download the modified file to the FieldServer and Reset the FieldServer for the changes to take effect.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Page 23
Image 23
FieldServer instruction manual FS-8700-103ATMITGMSerial Manual Message, Fyi

FS-8700-103 specifications

The FieldServer FS-8700-103 is an advanced gateway solution designed to facilitate seamless communication between different building automation systems and devices. Its primary function is to provide interoperability among various protocols and devices, which is increasingly important in modern facility management. The FS-8700-103 alleviates common challenges faced by system integrators, allowing for easy integration and operation of diverse systems from multiple manufacturers.

One of the standout features of the FieldServer FS-8700-103 is its support for multiple communication protocols. These include Modbus, BACnet, LonWorks, and SNMP, among others. This versatility allows the FS-8700-103 to serve as a bridge between legacy systems and newer technologies, thus extending the useful life of existing infrastructure while enabling the addition of advanced system capabilities.

The FS-8700-103 is equipped with numerous ports, including Ethernet connections, which support both wired and wireless communications. This flexibility ensures that the gateway can fit into various network configurations and adapt to different deployment scenarios. In addition, its robust design guarantees reliable performance even in demanding environments, making it suitable for use in commercial, industrial, and residential applications.

Another key characteristic of the FS-8700-103 is its intuitive web-based interface. This interface simplifies the configuration process, allowing users to set up the system with minimal technical expertise. The built-in diagnostic tools provide real-time monitoring and troubleshooting capabilities, enabling operators to quickly identify and address issues, thus reducing downtime and enhancing operational efficiency.

Security is also a notable feature of the FS-8700-103. With increasing concerns regarding cybersecurity in building management systems, this gateway incorporates advanced security protocols to protect data integrity and privacy. This ensures that sensitive information remains safeguarded against unauthorized access.

In summary, the FieldServer FS-8700-103 stands out as a reliable and versatile solution for achieving interoperability in building automation systems. Its support for multiple protocols, robust connectivity options, user-friendly interface, and strong security measures make it a valuable asset for any organization looking to streamline operations and enhance the effectiveness of their automation systems. With the FS-8700-103, organizations can move towards a more integrated and efficient future in facility management.