FS-8700-88 Envirotronics SystemsPlus

Table of Contents

4.4.90. Map Descriptor Example 86 - edit read number steps

36

4.4.91. Map Descriptor Example 87 - edit read duration

37

4.4.92. Map Descriptor Example 88 - edit read events

37

4.4.93. Map Descriptor Example 89 - edit read aux

38

4.4.94. Map Descriptor Example 90 - edit read cycles

38

4.4.95. Map Descriptor Example 91 - edit read next

39

4.4.96. Map Descriptor Example 92 - edit read analog min

39

4.4.97. Map Descriptor Example 93 - edit read analog max

39

4.4.98. Map Descriptor Example 94 - edit read analog type

40

4.4.99. Map Descriptor Example 95 - edit read engineering min

40

4.4.100.

Map Descriptor Example 96 - edit read engineering max

40

4.4.101.

Map Descriptor Example 97 - edit read analog address

41

4.4.102.

Map Descriptor Example 98 - edit read units

41

4.4.103.

Map Descriptor Example 99 - edit read fuzzy heat cycle time

41

4.4.104.

Map Descriptor Example 100 - edit read fuzzy cool cycle time

42

4.4.105.

Map Descriptor Example 101 - edit read fuzzy heat sensitivity

42

4.4.106.

Map Descriptor Example 102 - edit read fuzzy cool sensitivity

42

4.4.107.

Map Descriptor Example 103 - edit read fuzzy heat max. power

43

4.4.108.

Map Descriptor Example 104 - edit read fuzzy cool max. power

43

4.4.109.

Map Descriptor Example 105 - edit read fuzzy heat min. time

43

4.4.110.

Map Descriptor Example 106 - edit read fuzzy cool min. time

44

4.4.111.

Map Descriptor Example 107 - edit read fuzzy heat stage delay

44

4.4.112.

Map Descriptor Example 108 - edit read fuzzy cool stage delay

44

4.4.113.

Map Descriptor Example 109 - edit read fuzzy dead band

45

4.4.114.

Map Descriptor Example 110 - read alarm log

45

4.4.115.

Map Descriptor Example 111 - edit read setpoint channel

45

4.4.116.

Map Descriptor Example 112 - edit read gsoak enabled channel

46

4.4.117.

Map Descriptor Example 113 - edit read gsoak channel

46

4.4.118.

Map Descriptor Example 114 - edit read scan alarm

46

4.4.119.

Map Descriptor Example 115 - edit set scan alarm = Boolean

47

APPENDIX A.

PARAMETER TABLES

48

Appendix A.1. System plus data types

48

Appendix A.2.

Legal System PlusCommands

48

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldServer.com

Page 4
Image 4
FieldServer FS-8700-88 instruction manual Appendix a Parameter Tables

FS-8700-88 specifications

The FieldServer FS-8700-88 is a powerful device designed for industrial automation, building management systems, and process control applications. It serves as a communication gateway that enables seamless interoperability between diverse protocols and devices, addressing the increasing need for integration in modern industrial environments.

One of the standout features of the FS-8700-88 is its ability to support an extensive range of communication protocols. This includes popular options such as Modbus TCP, BACnet/IP, LonWorks, and SNMP, allowing users to connect equipment from different manufacturers without compatibility issues. This flexibility is essential for companies looking to maintain legacy systems while integrating new technologies.

The FS-8700-88 is built on a robust hardware platform that ensures reliable performance in demanding environments. It features an 88-point I/O module for real-time data acquisition and control, offering numerous input and output options to meet specific application requirements. This modular design allows for easy scalability as operations grow or change, making it ideal for both small installations and large-scale systems.

Moreover, the device incorporates advanced networking technologies such as Ethernet and serial communication, which enhance data transfer efficiency and system responsiveness. The ability to configure the device via a web-based interface provides added convenience, enabling users to adjust settings and monitor performance from anywhere with an internet connection.

Security is a top priority for industrial applications, and the FS-8700-88 is equipped with features to protect sensitive data. The device supports secure protocols and includes options for network segmentation, ensuring that critical systems remain safe from external threats.

In addition to its technical capabilities, the FS-8700-88 provides users with extensive diagnostic tools and logging features. These capabilities help streamline troubleshooting processes and enable proactive maintenance, ultimately reducing downtime and improving overall system reliability.

With its combination of versatility, robust performance, and strong security measures, the FieldServer FS-8700-88 sets a new standard in the field of industrial communication gateways. It empowers organizations to achieve higher levels of efficiency and integration across their automation systems, driving innovation and productivity in the process. As industrial environments continue to evolve, the FS-8700-88 is well-positioned to meet the challenges of tomorrow's connected world.