FTLF1217P2xTL Pluggable SFP Product Specification – September 2008

IX. Digital Diagnostic Specifications

FTLF1217P2xTL transceivers have internally calibrated digital diagnostics.

Parameter

Symbol

Min

Typ

Max

Units

Ref.

Accuracy

 

 

 

 

 

 

Internally measured transceiver

DDTemperature

 

 

± 3

ºC

 

temperature

 

 

 

 

 

 

Internally measured transceiver

DDVoltage

 

 

± 100

mV

 

supply voltage

 

 

 

 

 

 

Measured TX bias current

DDBias

 

 

± 10

%

1

Measured TX output power

DDTx-Power

 

 

± 3

dB

 

Measured RX received average

DDRx-Power

 

 

± 3

dB

 

optical power

 

 

 

 

 

 

Dynamic Range for Rated Accuracy

 

 

 

 

 

 

Internally measured transceiver

DDTemperature

-40

 

85

ºC

 

temperature

 

 

 

 

 

 

Internally measured transceiver

DDVoltage

3.0

 

3.6

V

 

supply voltage

 

 

 

 

 

 

Measured TX bias current

DDBias

0

 

70

mA

 

Measured TX output power

DDTx-Power

-22

 

-13

dBm

 

Measured RX received average

DDRx-Power

-33

 

-12

dBm

 

optical power

 

 

 

 

 

 

Max Reporting Range

 

 

 

 

 

 

Internally measured transceiver

DDTemperature

-40

 

125

ºC

 

temperature

 

 

 

 

 

 

Internally measured transceiver

DDVoltage

2.8

 

4.0

V

 

supply voltage

 

 

 

 

 

 

Measured TX bias current

DDBias

0

 

80

mA

 

Measured TX output power

DDTx-Power

-24

 

-11

dBm

 

Measured RX received average

DDRx-Power

-35

 

-10

dBm

 

optical power

 

 

 

 

 

 

Notes:

1. Accuracy of Measured Tx Bias Current is 10% of the actual Bias Current from the driver to the LED.

♥ Finisar Corporation September 13, 2008 Rev. B

Page 8

Page 8
Image 8
Finisar FTLF1217P2XTL manual IX. Digital Diagnostic Specifications, Parameter Symbol Min Typ Max Units Accuracy