FTLF1217P2xTL Pluggable SFP Product Specification – September 2008
IX. Digital Diagnostic Specifications
FTLF1217P2xTL transceivers have internally calibrated digital diagnostics.
Parameter | Symbol | Min | Typ | Max | Units | Ref. |
Accuracy |
|
|
|
|
|
|
Internally measured transceiver | DDTemperature |
|
| ± 3 | ºC |
|
temperature |
|
|
|
|
|
|
Internally measured transceiver | DDVoltage |
|
| ± 100 | mV |
|
supply voltage |
|
|
|
|
|
|
Measured TX bias current | DDBias |
|
| ± 10 | % | 1 |
Measured TX output power |
|
| ± 3 | dB |
| |
Measured RX received average |
|
| ± 3 | dB |
| |
optical power |
|
|
|
|
|
|
Dynamic Range for Rated Accuracy |
|
|
|
|
|
|
Internally measured transceiver | DDTemperature |
| 85 | ºC |
| |
temperature |
|
|
|
|
|
|
Internally measured transceiver | DDVoltage | 3.0 |
| 3.6 | V |
|
supply voltage |
|
|
|
|
|
|
Measured TX bias current | DDBias | 0 |
| 70 | mA |
|
Measured TX output power |
| dBm |
| |||
Measured RX received average |
| dBm |
| |||
optical power |
|
|
|
|
|
|
Max Reporting Range |
|
|
|
|
|
|
Internally measured transceiver | DDTemperature |
| 125 | ºC |
| |
temperature |
|
|
|
|
|
|
Internally measured transceiver | DDVoltage | 2.8 |
| 4.0 | V |
|
supply voltage |
|
|
|
|
|
|
Measured TX bias current | DDBias | 0 |
| 80 | mA |
|
Measured TX output power |
| dBm |
| |||
Measured RX received average |
| dBm |
| |||
optical power |
|
|
|
|
|
|
Notes:
1. Accuracy of Measured Tx Bias Current is 10% of the actual Bias Current from the driver to the LED.
♥ Finisar Corporation September 13, 2008 Rev. B | Page 8 |