Finisar FTLX8561E2 Electrical AC Characteristics, At near-end, No pre-equalization, 1 UI = 320 ps

Models: FTLX8561E2

1 10
Download 10 pages 55.5 Kb
Page 6
Image 6
Electrical AC Characteristics

FTLX8561E2 Product Specification – October 2008

Electrical AC Characteristics

(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)

Parameter

Symbol

XAUI Input AC Characteristics (TXLANE[0..3])

Baud Rate

RXAUIIN

Fibre Channel

 

Ethernet

 

Baud Rate Tolerance

RTOLXAUI

Differential Input Impedance

ZINXAUI

Differential Return Loss1)

S11

Input Differential Skew2)

tSKEWIN

Jitter Amplitude Tolerance3)

JXAUITOL

XAUI Output AC Characteristics (RXLANE[0..3])

min.

–100

80

10

Values

 

Unit

typ.

max.

 

 

 

3.1875

 

Gbit/s

 

 

3.125

 

 

 

100

ppm

100

120

 

 

dB

 

75

ps

 

0.65

UIp-p

Baud Rate

RXAUIOUT

Fibre Channel

 

Ethernet

 

Baud Rate Variation

RXAUIVAR

XAUI Eye Mask (far-end)

 

Output Differential Skew

tSKEWOUT

Output Differential Impedance

ZOUTXAUI

Differential Output Return Loss1)

S22

Total Jitter4)

TJXAUI

Deterministic Jitter4)

DJXAUI

Power-On Reset AC Characteristics

 

3.1875

 

Gbit/s

 

 

 

–100

3.125

 

 

 

100

ppm

According

to IEEE 802.3ae

 

80

 

15

ps

100

120

10

 

 

dB

 

 

0.35

UI

 

 

0.37

UI

Power-On Reset and TX_ONOFF

 

According to XENPAK MSA Issue 3.0, 2002-9-18

 

Characteristics

 

 

 

 

 

 

 

MDIO I/O AC Characteristics (MDIO;

MDC)

 

 

 

 

 

 

MDIO Data Hold Time

tHOLD

 

10

 

 

 

ns

MDIO Data Setup Time

tSU

 

10

 

 

 

ns

Delay from MDC Rising Edge to

tDELAY

 

 

 

300

 

ns

MDIO Data Change

 

 

 

 

 

 

 

MDC Clock Rate

ƒMAX

 

 

 

2.5

 

MHz

1)100 MHz to 2.5 GHz.

2)At crossing point.

3)Per IEEE Std 802.3ae.

4)At near-end, No pre-equalization, 1 UI = 320 ps.

© Finisar Corporation – October 2008

Rev B

Page 6

Page 6
Image 6
Finisar FTLX8561E2 manual Electrical AC Characteristics, 1 100 MHz to 2.5 GHz 2 At crossing point 3 Per IEEE Std 802.3ae