Finisar FTLX8561E2 Environmental Performance, Fibers and Connectors, pin Connector, Aqueous Wash

Models: FTLX8561E2

1 10
Download 10 pages 55.5 Kb
Page 8
Image 8
Environmental Performance

FTLX8561E2 Product Specification – October 2008

Environmental Performance

 

Operating case temperature:

0°C to +70°C

Operating humidity:

0% -95% RH non-condensing

Fibers and Connectors

The transponder has SC receptacles for both Tx and Rx. The transponder is designed for multimode SC cables, 0° polished endface (PC).

70-pin Connector

The module interface connector is a 70-pin, printed circuit board edge connection with a

0.5mm pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT, dual row, right angled, edge connector, 0.5 mm pitch (Tyco Electronics part number 1367337-1, Molex part number 74441-0003 or equivalent).

Rail and Mechanical Mounting Requirements

The XENPAK rail system required to mount the XENPAK module is fully defined by the MSA.

Aqueous Wash

Finisar XENPAK transponders are neither solderable nor aqueous washable and are not intended for these processes.

VI. Regulatory Compliance

Feature

Standard

Comments

ESD:

EIA/JESD22-A114-B

Class 1a (> 500 V)

Electrostatic Discharge to the

(MIL-STD 883D

 

Electrical Pins (HBM)

Method 3015.7)

 

Immunity:

EN 61000-4-2

Discharges ranging from ±2 kV to ±25 kV to

Against Electrostatic Discharge

IEC 61000-4-2

the front end / faceplate / receptacle cause no

(ESD) to the Module Receptacle

 

damage to module (under recommended

 

 

conditions).

Immunity:

EN 61000-4-3

With a field strength of 10 V/m, noise

Against Radio Frequency

IEC 61000-4-3

frequency ranges from 10 MHz to 2 GHz. No

Electromagnetic Field

 

effect on module performance between the

 

 

specification limits.

Emission:

FCC 47 CFR

Noise frequency range:

Electromagnetic Interference

Part 15, Class B

30 MHz to 40 GHz

(EMI)

EN 55022 Class B

Radiated emission does not exceed specified

 

CISPR 22

limits when measured with module inside a

 

 

shielding enclosure with a MSA conforming

 

 

cutout.

© Finisar Corporation – October 2008

Rev B