OPTIONAL POWERHOOD

Fig. 18-1

Hinge bolt

 

Locking bolt

CONFIGURING THE LID FOR AUTOMATIC OPENING AND CLOSING

The unit is shipped in this conÞ guration, but if you have conÞ gured it for manual operation and wish to use the automatic open/close function again, follow this procedure to conÞ gure for automatic operation:

1.Follow steps 1-4 on the previous page except screw in the locking bolt in step 3.

2.Switch the receiver to the AUTO position (see

SYNCHRONIZING TRANSMITTER AND RECEIVER instructions below.

TURNING ON THE TRANSMITTER

The transmitter has a AUTO/OFF switch, a sync. switch and an indicator LED on it.The AUTO/OFF switch must be in the Auto position for the remote transmitter to control the motorized oven lid.

INSTALLING/CHANGING THE BATTERIES IN THE TRANSMITTER

Slide open the battery access door on the back of the Power Hood remote. Remove the 12-volt camera battery and replace it. Close the access door and follow the instructions on synchronizing the remote below.

SYNCHRONIZING TRANSMITTER AND RECEIVER

The Þ rst time you turn on the transmitter or after changing batteries in the transmitter, it is necessary to synchronize the transmitter with the receiver.

To do this, use a pen to press in the synch button on the receiver (Fig. 18-2). The green LED will begin to

ßash. While the LED is ß ashing, press either the up or down button on the remote transmitter.The LED will go out. Then press the On/Off button on the transmitter.

The units are now synchronized. Test this by commanding the lid up or down as appropriate.

The units may be synchronized at any time.

Sync. button

AUTO/OFF

switch

Green LED

Fig. 18-2

ON/OFF

UP

Fig. 18-3

DOWN

18