3.Push the cable end through the hole on the cylinder manifold far enough to allow the flexible strand to be bent.

4.Place “S” hook through the hole in the MA lever.

5.Gently pull cable sheath back into manifold, aligning the groove in sheath with slot in the manifold.

6.Insert the wire retaining clip provided around the groove in the cable sheath through the slot in the manifold securing the cable.

WARNING:

With the “S” hook attached to the MA lever, and the wire retaining clip not properly installed, any pull on the cable exceeding 20lbs may actuate the fire extinguisher

Never install, remove or service the cable when the fire extinguisher is not securely mounted in its brackets

Always wear eye protection while servicing any component of your Fireboy fire extinguisher

Operation of Fireboy Fire Extinguisher

Automatic operation of CG2 and MA2 systems

Actuation of a Fireboy fire extinguisher occurs at 175°F (79°C) and is entirely dependent on the intensity of the fire

Manual operation of MA2 Systems

1.Do not wait for automatic actuation.

2.Close all hatches leading to the protected compartment.

3.Shutdown all forced ventilation devices, engines, generators and electrical systems.

4.Remove the safety pin from the “FIRE” T-handle, and pull firmly.

Signs of actuation

13

Page 13
Image 13
Fireboy- Xintex, LTD CG2, HFC-227ea, MA2 FE-241 owner manual Operation of Fireboy Fire Extinguisher

HFC-227ea, MA2 FE-241, CG2 specifications

Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 is an advanced fire suppression agent that stands out in its effectiveness and versatility. This halocarbon compound, also known as heptafluoropropane, has become a preferred choice for fire protection systems worldwide due to its unique chemistry and performance characteristics.

One of the main features of HFC-227ea is its ability to suppress flames without leaving behind damaging residues. This property makes it particularly suitable for use in sensitive environments like data centers, server rooms, and heritage sites where traditional water-based extinguishing systems could cause significant collateral damage. HFC-227ea operates effectively through a combination of cooling and chemical interruption of the combustion process.

The technology behind HFC-227ea is primarily rooted in its physical and chemical properties. It is a clean agent, meaning it does not conduct electricity, and it has a low boiling point, allowing it to vaporize quickly and fill a room efficiently. Its rapid vaporization facilitates swift deployment during a fire event, ensuring prompt control and suppression of flames. Moreover, this agent is recognized for its minimal impact on the environment, with a low ozone depletion potential and a global warming potential that is considerably lower than that of many other halon alternatives.

In terms of characteristics, the HFC-227ea system is designed to operate alongside various detection and control technologies. Fireboy Xintex utilizes advanced fire detection systems that can identify smoke and heat sources rapidly, enabling quick activation of the suppression system. This integration enhances overall fire safety and responsiveness.

Additionally, the system's modular design allows for easy scalability and customization according to the specific needs of different environments. Whether in maritime applications, industrial plants, or commercial infrastructures, the flexibility and adaptability of HFC-227ea make it a prominent choice in the fire suppression landscape.

In conclusion, Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 represents a cutting-edge solution in the field of fire protection. With its clean, efficient, and environmentally conscious characteristics, it not only meets the demands of modern fire safety but does so in a way that protects valuable assets and minimizes risk.