Fireboy- Xintex, LTD CG2, HFC-227ea, MA2 FE-241 owner manual Specifications

Models: HFC-227ea MA2 FE-241 CG2

1 18
Download 18 pages 20.82 Kb
Page 4
Image 4
Specifications

WARNING:

Never install a Fireboy system on the underside of a hatch cover or on an access door that may open or separate in an explosion

Never install the actuator of a Fireboy system in close proximity to exhaust manifolds or turbochargers. Radiated heat may cause premature actuation

Never install the actuator of a Fireboy system below the cylinder (Upside down)

Never install a Fireboy system where it will trap or be in direct contact with water

Never install a Fireboy unit in an compartment larger than its volume rating

Never combine the volume rating of two or more Fireboy units to protect a given compartment

This device shall not be installed or used in aircraft and/or racing vehicles

Diesel powered craft must also install the Automatic Engine Shutdown system or this system may not extinguish the fire (See Additional Equipment)

Specifications

When specifications listed on the nameplate label differ from this manual, the information listed on the nameplate label is correct.

CG2 and MA2 series extinguishers discharge automatically at a temperature of 175°F. MA2 series extinguishers discharge manually at any temperature.

Specification Tables and United States Coast Guard Approval Numbers

 

Volume

 

 

 

 

 

Agent

 

Approximate

 

 

 

 

 

 

 

 

 

 

 

 

 

Protected

 

Diameter

Total Height

Weight

 

Shipping Weight

 

Model Number

ft^3

m^3

in

cm

in

cm

lbs

kgs

lbs

kgs

U.S.C.G. #

CG2-025-FE241

25

0.71

3

8

9.1

23

0.8

0.4

6

2.7

162.029/175/0

CG2-050-FE241

50

1.4

3

8

12.2

31

1.7

0.8

8

3.5

162.029/176/0

CG2-075-FE241

75

2.1

4.3

11

11.9

30

2.5

1.2

9

3.9

162.029/177/0

CG2-100-FE241

100

2.8

4.3

11

14.5

37

3.4

1.5

12

5.6

162.029/178/0

CG2-125-FE241

125

3.5

4.3

11

14.5

37

4.2

1.9

13

6

162.029/179/0

CG2-150-FE241

150

4.3

5.1

13

13.1

33

5.1

2.3

15

6.9

162.029/180/0

CG2-175-FE241

175

4.9

5.1

13

15.5

39

5.9

2.7

16

7.2

162.029/180/0

CG2-200-FE241

200

5.7

5.1

13

15.5

39

6.8

3.1

17

7.6

162.029/181/0

CG2-225-FE241

225

6.4

6.4

16

14.7

37

7.6

3.5

26

11.6

162.029/181/0

CG2-250-FE241

250

7

6.4

16

14.7

37

8.5

3.8

26

12

162.029/182/0

CG2-275-FE241

275

7.8

6.4

16

14.7

37

9.3

4.2

27

12.4

162.029/182/0

CG2-300-FE241

300

8.5

7.2

18

15.1

38

10.1

4.6

32

14.6

162.029/182/0

CG2-325-FE241

325

9.2

7.2

18

15.1

38

11

5

33

15

162.029/183/0

CG2-350-FE241

350

10

7.2

18

15.1

38

11.8

5.4

34

15.4

162.029/183/0

CG2-375-FE241

375

10.6

7.2

18

17.8

45

12.7

5.8

36

16.2

162.029/183/0

CG2-400-FE241

400

11.3

7.2

18

17.8

45

13.5

6.1

37

16.6

162.029/183/0

CG2-450-FE241

450

12.7

7.2

18

17.8

45

15.2

6.9

38

17.4

162.029/184/0

CG2-500-FE241

500

14.1

7.2

18

24.7

63

16.9

7.7

47

21.3

162.029/184/0

4

Page 4
Image 4
Fireboy- Xintex, LTD CG2, HFC-227ea, MA2 FE-241 owner manual Specifications