NOTE:

Never push the cable at the T-handle end. Cable may jam and become inoperable.

Fixing a jammed cable:

1.Turn the T-handle and threaded metal rod counter clockwise ½ turn until the jam releases.

2.If necessary, use a pair of pliers to carefully twist the threaded metal rod until the jam releases.

3.Pull the cable from the “S” hook until the cable returns to an operational position.

4.Do not connect cable to cylinder at this time.

Routing the cable:

1.Locate the escutcheon plate (2 ½” x 4” with 13/32 hole) for the manual release handle.

At the helm station

On a firm support

In full view of the operator

With enough clearance for the cable ferrule to extend approximately 12 inches behind the panel

2.Using the escutcheon plate as a template, locate and drill a 13/32” hole.

3.Route the cable in the most direct manner, with as few bends as possible, to the cylinder location.

Do not bend in a radius of less than 6 inches (a 12 inch circle)

Follow the same route as manufacturer installed cables, if possible (Example: Steering, throttle, and transmission cables)

Do not subject cable to pinching or crushing, rubbing, extreme vibration, sharp bending or kinking, or extremes of heat or cold

Do not exceed 360° of bends (Example: Four 90° bends = 4 x 90° = 360°)

Use the shortest allowable cable whenever possible

If excess cable must be coiled; do not coil excess cable in the protected enclosure

4.Secure loose sections of the cable with the included nylon clamps.

Do not clamp cable in a bend

Do not crush cable with clamps

Escutcheon Panel and T-Handle

1.Ensure temperature is above +50°F (10°C) for proper adhesion.

2.Peel the release paper from the back of the escutcheon plate.

3.Align the larger hole with the 13/32 hole drilled in dash.

4.Press escutcheon plate down evenly to activate adhesive.

5.Following figure below, place nut and lock washer in place on the cable end and insert through the 13/32” hole in the panel and escutcheon.

11

Page 11
Image 11
Fireboy- Xintex, LTD MA2 FE-241, HFC-227ea, CG2 owner manual Do not connect cable to cylinder at this time

HFC-227ea, MA2 FE-241, CG2 specifications

Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 is an advanced fire suppression agent that stands out in its effectiveness and versatility. This halocarbon compound, also known as heptafluoropropane, has become a preferred choice for fire protection systems worldwide due to its unique chemistry and performance characteristics.

One of the main features of HFC-227ea is its ability to suppress flames without leaving behind damaging residues. This property makes it particularly suitable for use in sensitive environments like data centers, server rooms, and heritage sites where traditional water-based extinguishing systems could cause significant collateral damage. HFC-227ea operates effectively through a combination of cooling and chemical interruption of the combustion process.

The technology behind HFC-227ea is primarily rooted in its physical and chemical properties. It is a clean agent, meaning it does not conduct electricity, and it has a low boiling point, allowing it to vaporize quickly and fill a room efficiently. Its rapid vaporization facilitates swift deployment during a fire event, ensuring prompt control and suppression of flames. Moreover, this agent is recognized for its minimal impact on the environment, with a low ozone depletion potential and a global warming potential that is considerably lower than that of many other halon alternatives.

In terms of characteristics, the HFC-227ea system is designed to operate alongside various detection and control technologies. Fireboy Xintex utilizes advanced fire detection systems that can identify smoke and heat sources rapidly, enabling quick activation of the suppression system. This integration enhances overall fire safety and responsiveness.

Additionally, the system's modular design allows for easy scalability and customization according to the specific needs of different environments. Whether in maritime applications, industrial plants, or commercial infrastructures, the flexibility and adaptability of HFC-227ea make it a prominent choice in the fire suppression landscape.

In conclusion, Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 represents a cutting-edge solution in the field of fire protection. With its clean, efficient, and environmentally conscious characteristics, it not only meets the demands of modern fire safety but does so in a way that protects valuable assets and minimizes risk.