The professional choice in fire safety.
|
|
| Duct Smoke Detectors | |
|
|
| Universal Voltage Models | |
|
|
| 230 VAC, 115 VAC, 24 VAC or 24 VDC operation | |
|
|
|
| |
|
| |||
FIREX® the recognized leader in residential fire protection, | Air sampling is accomplished by two tubes, which | |||
brings you the latest in duct smoke detection technology. | protrude into the duct. An exhaust tube of one standard | |||
FIREX® Duct Smoke Detectors provide early detection of | length (7'') is provided with each FIREX® Duct Smoke | |||
smoke and products of combustion present in air moving | Detector. Intake sampling tubes, which must be ordered | |||
through an HVAC duct. These devices are designed for | separately, are available in three standard lengths. | |||
prevention of smoke recirculation in areas by the air | Duct smoke detector mounting is accomplished by the use | |||
handling systems. Fans, blowers, and complete systems | ||||
of a mounting template and four sheet metal screws, | ||||
may be shut down in the event of smoke detection. Our | ||||
which are provided. | ||||
universal voltage models will operate on any one of | ||||
| ||||
four input voltages. |
| |||
|
|
| High Temperature Design | |
|
|
| Rated to 155˚F (ionization model) | |
Alerts When Dirty | for rooftop and other installations | |||
where high temperatures can | ||||
Automatically indicates when | ||||
cause problems. | ||||
maintenance is required. | ||||
|
Interconnect |
| Front Mounted |
Up to 30 Models |
| |
Up to 30 models can be |
| Test / Reset Button |
interconnected to provide |
| Provides quick and accurate |
complete HVAC system |
| testing of system. |
|
| |
|
| |
connected blowers, fans |
|
|
and dampers. |
| Installation Flexibility |
|
| |
|
| Fast and easy mounting to |
|
| rectangular ducts. |
Additional Features
•Four sheet metal screws provide easier mounting
•UL 268A Listed
•Factory set tube alignment
•Mechanical installation without cover removal
•
•Installation template included
•Large terminal connection screws
•Power supervisory relay included
•Two independent form “C” alarm contacts standard
• | Compatible with building automation & fire alarm systems | |
• | Dust filtering included in detector head |
|
• | No additional screens or filters to clean |
|
• | Common or individual remote reset |
|
• | Common or individual fan shutdown relay operation |
|
• | Common or individual remote alarm indication, |
|
| i.e. red LED, horn, strobe |
|
• | Common or individual head removed remote indication |
|
• | One horn/strobe operated by up to 15 detectors | T |
|