Firex FADC manual Troubleshooting, Warranty Information

Models: FADC

1 8
Download 8 pages 6.74 Kb
Page 8
Image 8
TROUBLESHOOTING

TROUBLESHOOTING

! DANGER: Always turn off power at main fuse box or circuit breaker before taking trouble- shooting action.

!WARNING: DO NOT disconnect battery or AC power to quiet an unwanted alarm. This will remove your protection. Fan the air or open a window to remove smoke or dust.

PROBLEM

SOLUTION

 

 

Smoke alarm does not

1. Check that AC power

sound when tested.

is turned on.

NOTE: Push test button for

2. Turn off power. Remove smoke

alarm from mounting plate and:

at least five (5) seconds while

a. check that connector

testing!

plug is securely attached.

 

b. check that battery is proper-

 

ly attached to connector.

 

3. Clean smoke alarm.

 

 

LED blinks and alarm beeps

Battery is low – REPLACE IT

simultaneously every 60 seconds.

IMMEDIATELY!

 

 

LED blinks and 30 seconds later

Unit inoperable. REPLACE OR

alarm beeps – repeats at 60

RETURN FOR REPAIR

second intervals.

IMMEDIATELY!

 

 

Smoke alarm beeps about

Turn off power and replace

once a minute.

battery. See “Battery Replacement”

 

in the MAINTENANCE AND

 

CLEANING section.

 

 

Smoke alarm sounds

1. Clean smoke alarm.

unwanted alarms intermit-

See “Cleaning” in the

tently or when residents

MAINTENANCE AND

are cooking, taking

CLEANING section

showers, etc.

2. Hire an electrician to move

 

smoke alarm to a new location.

 

See SMOKE ALARM

 

PLACEMENT

 

 

Interconnected smoke

Press and hold test button for at

alarms do not sound when

least three seconds after the first

system is tested.

unit sounds.

 

 

The alarm sounds different

The alarm is operating correctly

than I’m used to. It starts and

This alarm features the

stops.

internationally recognized horn

 

signal for evacuation. The horn

 

pattern is 3 short beeps followed

 

by a 2 second pause and then

 

repeats.

 

 

REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOL- LOWING THE PROCEDURES OUTLINED ABOVE (see REPAIR on page 7).

WARRANTY INFORMATION

5-YEAR LIMITED SMOKE ALARM WARRANTY AND

10-YEAR LIMITED ULTRALIFE U9VL-J LITHIUM BATTERY WARRANTY (WHEN SOLD WITH INVENSYS CONTROLS AMERICAS SMOKE ALARM)

Invensys Controls Americas warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and workmanship under normal use and service for a period of five (5) years from the date of purchase. For Invensys Controls Americas smoke alarms sold with an Ultralife U9VL-J 9-volt battery, Invensys Controls Americas warrants to the original consumer purchaser each new Ultralife U9VL-J 9-volt battery to be free from defects in material and workmanship under normal use and service for a period of ten (10) years from the date of purchase. Invensys Controls Americas agrees to repair or replace, at its option, any defective smoke alarm or Ultralife U9VL-J 9-volt battery (when sold with Invensys Controls Americas smoke alarm) provided that it is returned with postage prepaid and with proof of pur- chase date to Invensys Controls Americas. This warranty does not cover damage resulting from accident, misuse or abuse or lack of reasonable care of the product. This warranty is in lieu of all other express warranties, obligations or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERI- OD OF FIVE (5) YEARS FOR THE SMOKE ALARM AND TEN (10) YEARS FOR THE ULTRALIFE LITHIUM U9VL-J 9-VOLT BATTERY (WHEN SOLD WITH INVENSYS CONTROLS AMERICAS SMOKE ALARM) FROM PURCHASE DATE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. IN NO CASE SHALL INVENSYS CONTROLS AMERICAS COMPANY BE LIABLE FOR ANY INCIDENTAL OR CON- SEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. This smoke alarm’s manufacture and distribution are licensed by the U.S. Nuclear Regulatory Commission. This product meets all the requirements of U.L. Standard 217.

191 E. North Avenue

 

Carol Stream, Illinois 60188 USA

 

www.invensyscontrols.com

 

©2006 Invensys Controls

110-628F

8

Page 8
Image 8
Firex FADC manual Troubleshooting, Warranty Information