Firex FADC manual False Alarm Control, Interconnecting Smoke Alarms, Red And Green Led Indicators

Models: FADC

1 8
Download 8 pages 6.74 Kb
Page 5
Image 5
INTERCONNECTING SMOKE ALARMS

NOTE: If this will be a single-station smoke alarm, cover yellow wire with electrical tape and tuck into junction box.

8.Lift open battery pocket door.

9.Connect new 9-volt battery to battery connector inside battery

pocket. BE SURE BATTERY IS

Remove thin plastic

SECURELY CONNECTED. Smoke

from notch

alarm may beep briefly when bat-

 

 

tery is installed.

 

10.Close battery pocket door, snapping it into place. (For tam- per-resist, use long-nosed pliers to remove thin plastic from notch on smoke alarm edge.)

11.Attach connector plug to pins on back of smoke alarm. Plug will only fit one way and will snap

into place.

Insert pin here

 

12.Gently tug connector to be sure it is attached securely.

13.Position smoke alarm to mounting plate and turn clockwise to lock into

place. To engage tamper-resist feature, insert pin into notch on edge of smoke alarm after alarm is properly positioned in base. (See instruction #10.)

NOTE: Smoke alarm will not mount to plate if battery is not installed.

14.Turn on power at main fuse box or circuit breaker.

15.Test smoke alarm. See TESTING THE SMOKE ALARM.

WHITE

WHITE

WHITE

YELLOW

YELLOW

TO NEUTRAL

 

BLACK

BLACK

BLACK

 

 

TO 120 VAC

INTERCONNECTING SMOKE ALARMS

This smoke alarm may be interconnected with as many as 11 other Firex model FADC, AD and ADC smoke alarms, or as many as 6 Firex model ADH heat alarms for a total of not more than 18 interconnected devices. DO NOT connect to any other type or model smoke alarm.

Connect smoke alarms to a single AC branch circuit. If local codes do not permit, be sure the neutral wire is common to both phases.

RED AND GREEN LED INDICATORS

This smoke alarm features separate red and green LED indicators. The LEDs indicate the following:

GREEN LED

 

CONSTANT ON

— AC power is present.

OFF

— AC power is not present.

RED LED

— Can be seen through the

 

Push-to-Test button.

Blinks once a minute

— Indicating presence of a work-

 

ing battery.

Blinks once a second

— Smoke alarm senses smoke

 

and simultaneously sounds

 

an audible alarm.

Blinks once every 10 seconds — Smoke alarm is quieting an unwanted alarm (Model ADC only).

(Interconnected system only):

OFF — Another smoke alarm in the network has sensed smoke and is signalling this alarm.

FALSE ALARM CONTROL

Model ADC features a False Alarm Control that, when activated, quiets unwanted alarms for up to 15 minutes.

To use the False Alarm Control:

Press and release the test button during an unwanted alarm. The alarm should stop within ten seconds. This means the smoke alarm is in False Alarm Control.