Firex pmn CO Alarm Features cont, Where to Install Your CO Alarm, DO NOT install CO alarms

Models: pmn

1 16
Download 16 pages 15.6 Kb
Page 3
Image 3
CO Alarm Features (cont.)

CO Alarm Features (cont.)

!WARNING

This CO alarm is designed to detect carbon monoxide gas from any source of combustion. It is NOT designed to detect smoke, fire, or any other type of gas. If this CO alarm sounds its alarm horn, DO NOT assume that it is a false alarm. The alarm horn requires your immediate action.

!WARNING

This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards.

Where to Install Your CO Alarm

!WARNING

Carbon monoxide gas can be anywhere and everywhere. CO gas is equal to or slightly lighter than air, and disperses evenly with the air in a room. Therefore, install this CO alarm where air circulation is best. DO NOT mount the CO alarm within 1 foot of the ceiling/wall or wall/wall intersection, or other dead air spaces.

Since most CO fatalities occur while families are sleeping, we recommend that you install at least one CO alarm in the hallway outside each separate sleeping area and one inside each bedroom or sleeping area.

We also recommend that you install a CO alarm on every separate living level of the home where household members frequently spend time, as well as in the basement. See Figures 1, 2, and 3 for typical CO alarm loca- tions within the home.

This alarm can share the interconnect wire of smoke and heat alarms, BUT this alarm will remain silent if smoke is detected by the interconnected smoke and heat alarms. Therefore, it is necessary to install both a CO alarm and smoke alarm in those areas to be protected.

!CAUTION

This alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.

LIVED-IN ATTIC

BEDROOM

BEDROOM

BATH

 

 

FURNACE

 

 

ROOM

BASEMENT

 

 

single story

FIGURE 1

BEDROOM

BATH

BEDROOM

LIVING

 

KITCHEN

ROOM

 

 

 

 

 

FURNACE

BASEMENT

 

ROOM

 

 

two story

FIGURE 2

BEDROOM

BATH

BEDROOM

 

 

 

 

 

FAMILY / GREAT ROOM

BATH

 

 

 

 

 

 

KITCHEN

 

 

LIVING

 

 

 

 

ROOM

 

 

 

 

BASE-

 

UTILITY

split level

 

 

ROOM

 

 

MENT

 

 

 

 

Key

FIGURE 3 CO alarm locations

!WARNING

DO NOT install CO alarms:

Near bathrooms or in shower areas. Steam and aerosol sprays can dis- able the alarm.

In closets, crawlspaces, unused attics, or unheated areas where sur- rounding air temperatures may go below 40°F (4.4°C) or above 100°F (37.8°C).

Within five feet of any fuel-burning appliance (stove, kerosene heater, fur- nace, fireplace, etc.).

Within one foot of any wall, corner, or other dead air spaces.

In rooms where chemicals or cleaning supplies are frequently used (paint, hair spray, thinner, etc.). Allow plenty of ventilation in rooms where chemi- cals are used.

Directly above a sink, bathtub or basin.

Directly above or below air exchange or heating vents.

Behind drapes, furniture, or appliances that could block air flow to the

CO alarm.

! WARNING

 

This unit cannot be used in recreational vehicle applications.

Español

bustibles se queman sin que haya una cantidad suficiente de oxígeno (combustión incompleta). Este tipo de mal funcionamiento puede ocurrir en cualquier artefacto que queme combustible y en cualquier momento. Por ejemplo, muchas chimeneas se pueden llenar de hojas en el otoño, y si hay una suficiente cantidad de hojas, se acumulará suciedad y hollín en la chimenea y se interrumpirá la ventilación adecuada. Esto puede hacer que el CO entre a la casa y el resultado puede ser fatal. Sin embargo, con un mantenimiento y limpieza adecuados se puede reducir la posibilidad de acumulación de CO.

El envenenamiento con monóxido de carbono es un asunto grave. Muchas familias lo sufren todos los días, y más de mil vidas se pierden cada año debido a este gas casero mortal. Si se mantiene y cuida adecuadamente, la alarma de CO le puede dar a los miembros de la familia una advertencia anticipada de las emisiones de CO. Sírvase leer bien este manual para aprender cómo instalar, operar, limpiar y reparar adecuadamente la alarma de CO, así como para enterarse de recomendaciones importantes sobre seguridad a fin de proteger a su familia del envenenamiento fatal con CO.

Los símbolos siguientes identifican los mensajes importantes sobre seguridad que hay en este manual

!PELIGRO

Cuando vea este símbolo, usted debe saber que, si no se toma en cuenta el mensaje, la situación peligrosa CAUSARÁ lesiones corporales GRAVES o la muerte.

!ADVERTENCIA

Cuando vea este símbolo, usted debe saber que, si no se toma en cuenta el mensaje, la situación peligrosa PUEDE CAUSAR lesiones corporales GRAVES o la muerte.

!CUIDADO

Cuando vea este símbolo, usted debe saber que, si no se toma en cuenta el mensaje, la situación peligrosa PUEDE causar o CAUSARÁ lesiones corporales leves.

3

Page 3
Image 3
Firex pmn owner manual CO Alarm Features cont, Where to Install Your CO Alarm, DO NOT install CO alarms