How to Install Your CO Alarm

Once you have decided the best place to install the CO alarm(s), follow these steps:

!WARNING

ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF position.

!CAUTION

Check local codes for specific mounting require-

ments in your area.

1. From back of CO alarm, slide mounting plate and lift from base. See Figure 4.

2. Connect new 9-volt battery to battery connector

 

inside compartment and slide door closed

 

snapping it into place. New 9V battery comes

 

from the factory installed backwards inside the

 

battery compartment. Replace battery with

FIGURE 4

Eveready 216, 522, 1222 or equivalent from your

local retailer.

3.Align mounting plate with junction box mounting holes.

4.Gently pull household wires through center hole of mounting plate.

5.Secure mounting plate to junction box.

6.With a small wire connector, connect white wire from the CO alarm to white household wire.

7. Connect black wire from the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO alarm to the black house-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hold wire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. For interconnecting alarms:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Use #18 AWG minimum

 

 

 

WHITE

 

 

WHITE

 

 

WHITE

solid or stranded wire. When

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

 

 

YELLOW

 

 

 

TO NEUTRAL

interconnecting, maximum

 

 

 

BLACK

 

 

BLACK

 

BLACK

 

wire length between any two

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO 120 VAC (HOT)

is 1,500 feet for #18 AWG or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 5

4,000 feet for #14 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(20 OHMS loop resistance.) See Figure 5.

This CO alarm may be interconnected with as many as 11 other Firex CO alarms or with as many as 12 Firex smoke alarms, and 5 CO or heat alarms for a total number of 18 units.

This CO alarm may be interconnected with Firex models FADC, ADC, PAD and ADH smoke and heat alarms. DO NOT connect to any other model CO, smoke or heat alarm.

Note that this CO alarm will not cause interconnected smoke and

heat alarms to sound their horn. This CO alarm will remain silent if inter- connected smoke and heat alarms are sounding even if there is a build- up of CO.

• Connect CO and smoke alarms to a single AC branch circuit. If local

codes do not permit connection to a

FIGURE 6

single AC branch circuit, be sure the

 

neutral wire is common to all circuits used.

 

9.Align tabs on back of base with slots on side of mounting plate. Slide base down to lock into position. See Figure 6.

10.Turn power on at the main fuse box or circuit breaker. The CO alarm will flash the red LED and emit a short beep during its power-up cycle. The green POWER light will stay on as long as the CO alarm is receiving AC power.

Español

!ADVERTENCIA

CONOZCA LAS FUENTES COMUNES DE MONÓXIDO DE CARBONO. Las fuentes comunes de monóxido de carbono son calderas para calefacción, aparatos para calentar, calentadores de agua, cocinas o estufas a gas, calentadores a queroseno, chimeneas, parrillas que se usan dentro de la casa, motores o máquinas que estén funcionado en garajes unidos a la casa y dispositivos a gasolina como los generadores y las bombas que se usan en emergencias. Conozca cómo usar adecuadamente cada aparato o dispositivo y haga que les den servicio y se limpien regularmente. Use el sentido común y siga cuidadosa- mente las instrucciones sobre seguridad y riesgos siempre que los use.

!ADVERTENCIA

Las personas con problemas médicos pueden considerar usar dispositivos de advertencia que tengan señales audibles o visuales para concentraciones de monóxido de carbono por debajo de 30 ppm.

Características de la alarma de CO

Pila de repuesto de 9 V

Arnés para conexión rápida de los alambres para facilitar y abreviar la instalación

Interconexión inteligente: cable compartido de interconexión con el cual las alarmas de humo distinguen entre las señales de alarma de hum y de monóxido de carbono en el cable de interconexión

Su forma cuadrada la diferencia claramente de las alarmas de humo

Botón grande para probar y recalibrar: fácil de usar

Sistema de alarma de luz y sonido de tres niveles; usted siempre sabe si:

1.La unidad está recibiendo la corriente alterna.

2.La alarma requiere cambiarse de inmediato.

3.Hay niveles peligrosos de CO.

Especificaciones eléctricas: 120 V de CA, 60 Hz, 0,05 amp.