CO ALARM SPECIFICATIONS
Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.
Required Alarm Levels: Before 10% COHb exposure at levels of 30% to 70% Relative Humidity (RH):
•400 ppm CO between 4 and 15 minutes
•150 ppm CO between 10 and 50 minutes
•70 ppm CO between 60 and 240 minutes
The unit is designed not to alarm when exposed to a constant level of 30 ppm
for 30 days.
Audible Alarm: 85dB minimum at 10 feet
Power: Powered by 9V battery. Green light flashes about twice a minute when device is receiving battery power.
During Alarm: CO Alarm horn sounds while the red light flashes rapidly.
This CO alarm is designed to sound for up to 12 hours in alarm conditions, provided the battery is fresh and installed correctly.
Warranty:
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034.