1. Close the battery compartment by sliding the mounting bracket/battery door back onto the back of the CO Alarm.

2.Test the CO Alarm as described below.

3.Set the CO Alarm in plain view on a table where it will not be blocked by any obstructions.Table height should not exceed 36” (92 cm).

IMPORTANT!

Put the CO Alarm where children and pets cannot reach it.

To Test this CO Alarm:

Push and hold the Test/Silence button on the cover until you hear a “chirp.” The “chirp” marks the start of the self-test sequence.

First, the yellow and green lights will flash briefly—this is normal.

Next, the alarm horn will sound: 4 beeps, a pause, then 4 beeps. The red light will flash quickly.

The alarm sequence should last 5-6 seconds. If it does not alarm, make sure the battery is correctly installed, and test it again. If the unit still does not alarm, replace it immediately.

To Mount On The Wall

Tools you will need: pencil, drill with 3/16” or 5mm drill bit, flathead screwdriver, hammer.

1.Choose a location on the wall. Do not install the alarm closer than 4” from where the wall meets the ceiling.

2.Hold the mounting bracket

against the wall, and make a mark inside each To Mount On The Wall keyhole where you will drill your mounting hole.

3.Use a 3/16” drill bit to drill

through the marks you made for the mounting holes.

4.Insert the plastic screw anchors into the mounting holes until they are flush with the wall. If necessary, tap them gently with a hammer.

5.Line up the mounting bracket up with the

screw anchors, and screw the bracket onto

the wall.

6. Slide the CO Alarm

onto the mounting bracket until you feel it click into place.

7.Test the CO Alarm as described in “To Test this CO Alarm.”