6<67(029(59,(:
About the Display and Indicators
Display Definitions (for other displays, see Trouble Messages on page 27)
ALARM: Appears when an intrusion has been detected and the system is armed (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone in alarm.
AWAY LOW BAT AC INSTANT CHIME TEST
STAY REC MESSAGE ALARM FIRE BYPASS FAULT
AWAY: All burglary zones, interior and perimeter, are armed.
INSTANT: Entry delay is turned off.
STAY:Perimeter burglary zones, such as protected windows and doors, are armed.
FIRE:Appears when a fire alarm or fire fault is present. Accompanied by a display of the zone in alarm.
LOW BAT: Low battery condition in a wireless sensor (if zone number is displayed) or low system battery (if no zone number is displayed). If 00 is displayed, a wireless keypad (5827/5827BD) has a low battery condition.
AC:Appears when AC power is present. If not lit, the system is operating on backup battery power.
CHIME: Appears when the Chime feature is activated.
TEST:Appears when the system is in Test mode.
REC:Appears when in Recording mode.
MESSAGE: Appears when a message has been recorded and has not yet been played back.
BYPASS: One or more burglary protection zones have been bypassed.
FAULT: Appears when a malfunction is discovered in the system at any time; or if an open is detected in a fire zone at any time; or when a fault in a day/night burglary zone is discovered during a disarmed period. Accompanied by a display of the zone number in trouble.
LED Meanings
ARMED (Red) LED: ON = System armed
OFF = System disarmed
Blinking = System armed, but a fault exists
READY (Green) LED: ON = System disarmed, ready to arm
Blinking = System disarmed, not ready to arm (a fault exists)
NOTE: When the system is armed, the READY LED turns off.