10
Installation instructions
Connecting the cooktop to the mains power supply
Important!
This cooktop must be connected to the mains power supply only by a suitably qualified person. This cooktop must be earthed.
Before connecting the cooktop to the mains power supply, check that:
1the domestic wiring system is suitable for the power drawn by the cooktop
2 the voltage corresponds to the value given on the rating plate
3the power supply cable sections can withstand the load specified on the rating plate.
To connect the cooktop to the mains power supply, do not use adapters, reducers, or branching devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its temperature will not exceed 75oC at any point.
Power supply
CE604DT 6400W @
CE704DT 6400W @
CE754DT 7300W @
Fig. 4 Opening the terminal block cover
Connection diagrams
Single-phase connection
220 - 240 V
|
| 2 |
|
| 4 |
|
|
|
| ||
|
|
|
|
|
|
|
| ||||
1 |
|
| 3 |
|
| 5 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L1 N (L2) PE
2 |
| 4 |
1 | 3 | 5 |
|
| PE |
| L1 | N L2 |
|
|
Two-phase connection
380 - 415 V 2N | ||||
2 |
| 4 |
|
|
1 | 3 |
| 5 |
|
L1 L2 | N | PE | ||
2 |
| 4 |
|
|
1 | 3 |
| 5 | PE |
|
|
|
| |
| L1 | L2 |
| N |
|
|
|
|
Bridging links
removed | ~ | |
|