Installation instructions
Connecting the cooktop to the gas supply
9
The gas connection must be carried out by an authorised person according to the relevant standards.
Before connecting the appliance to the gas main, mount the brass conical adaptor onto the gas inlet pipe, upon which the washer has been placed (Figs. 5 and 6).
Conical adaptor and washer are supplied with the appliance (packed with conversion kit for use with Natural gas or LPG).
This appliance is suitable for use with Natural gas or LPG. (Check the “gas type” sticker attached to the appliance).
For Natural Gas, connect the gas supply to the gas pressure regulator which is supplied with the appliance (Fig. 5). Adjust the regulator to obtain a test point pressure of 1 kPa with the two
For LPG, connect the gas supply to the test point adaptor which is
supplied with the appliance (Fig. 6). Ensure that the supply pressure is regulated to 2.75 kPa. Do NOT force the ”elbow“ to rotate before loosening the floating nut.
Do NOT overtighten the floating nut at the ”elbow“.
Gas connection for | Gas connection for |
NATURAL GAS | LPG |
Gas inlet pipe
Gas inlet pipe
Washer
Elbow
Floating nut
Washer
Floating nut
Elbow
Test point
Brass conical adaptor (Thread tight: use suitable seal)
Gas pressure
regulatorTest point
Brass conical adaptor (Thread tight: use suitable seal)
Test point adaptor