3.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A

B

C

E

D

A. Terminal block

B.Ground-link screw

C.Cord/conduit plate

D.Power supply cord wires - large opening

E.Small opening

4.Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw. The ground wire must be attached first.

5.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the #10-32 hex nuts.

3-wire connection: Power Supply Cord

Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.

1.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A

B

C

E

D

A. Terminal block

B.Ground-link screw

C.Cord/conduit plate

D.Power supply cord wires - large opening

E.Small opening

2.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the #10-32 hex nuts.

A

F

 

B

 

C

E

 

 

D

A. #10-32 hex nut

D. Green ground wire

B. Ground-link screw

E. Neutral (center) wire

C. Line 1 (black)

F. Line 2 (red)

6.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with #10-32 hex nuts.

7.Securely tighten hex nuts.

NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

8.Replace terminal block access cover.

A

E

 

B

D

 

C

 

A. #10-32 hex nut

D. Neutral (white) wire

B. Line 1 (black)

E. Line 2 (red)

C.Ground-link screw

3.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with #10-32 hex nuts.

4.Securely tighten hex nuts.

NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

5.Replace terminal block access cover.

8

Page 8
Image 8
Whirlpool W10258095A installation instructions #10-32 hex nut Green ground wire Ground-link screw