Electrical Connection

Power Supply Cord

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct Wire

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.Disconnect power.

2.Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range.

3.Remove plastic tag holding three #10-32 hex nuts from the middle post of the terminal block.

4.Add strain relief.

Style 1: Power supply cord strain relief

Assemble a UL listed strain relief in the opening.

A

B

A. UL listed strain relief - large opening

B. Small opening

Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the power supply cord.

Style 2: Direct wire strain relief

Use Phillips screwdriver to remove screws and rotate/ conduit plate 180º.

B

A

A. Large opening

B. Small opening