Whirlpool W10258095A Installation Instructions, Unpack Range, If connecting to a 3-wire system

Models: W10258095A

1 12
Download 12 pages 62.59 Kb
Page 4
Image 4
If connecting to a 3-wire system:

The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.

4-wire receptacle (14-50R)

The minimum conductor sized for the copper 4-wire power cord are:

40-amp circuit

2 No.-8 conductors

1No.-10 white neutral

1No.-8 green grounding

If connecting to a 3-wire system:

Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.

3-wire receptacle (10-50R)

INSTALLATION INSTRUCTIONS

Unpack Range

INSTALLATION INSTRUCTIONSWARNING

Excessive Weight Hazard

Use two or more people to move and install range. Failure to do so can result in back or other injury.

1.Remove shipping materials, tape and film from range.

2.Remove oven racks and parts package from inside oven.

3.Do not remove the shipping base at this time.

AUnpack Range

A. Shipping base

4.On Ranges Equipped with Storage Drawers:

Remove the storage drawer. If a range height adjustment is necessary, use a ¼" drive ratchet to lower the rear leveling legs one-half turn. Use a wrench or pliers to lower front leveling legs.

A

D

C

B

A. ¼" drive ratchet

B. Rear leveling leg

C. Wrench or pliers

D. Front leveling leg

On Ranges Equipped with Warming Drawers:

If a range height adjustment is necessary, use wrench or pliers to lower the front and rear leveling legs.

A B

C

A. Rear leveling leg B. Front leveling leg C. Wrench or pliers

4

Page 4
Image 4
Whirlpool W10258095A Installation Instructions, Unpack Range, If connecting to a 3-wire system, Excessive Weight Hazard