Weber 89962 manual Refilling the Liquid Propane Cylinder, Check, Reinstall Control Panel

Models: 89962

1 68
Download 68 pages 22.53 Kb
Page 12
Image 12

GAS INSTRUCTIONS

Check

A)Hose-to-manifold connection (1)..

B)Side burner hose-to-manifold connection and side burner hose-to-side burner gas line connection (2)..

C)Side burner hose-to-side burner connection, side burner valve and orifice connections (3)..

mWARNING: If there is a leak at connection (1, 2, or 3), re- tighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after re-tightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

D)Regulator-to-cylinder connection (4)..

E)Hose-to-regulator connection (5)..

F)Valves-to-manifold connections (6)..

mWARNING: If there is a leak at connections (4, 5 or 6), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water..

Reinstall Control Panel

You will need: Phillips screwdriver..

A)Reconnect the igniter wires to the ignition module..

B)Carefully position control panel down and onto frame..

C)Reinstall machine screws at lower left and right side of control panel with a Phillips screwdriver..

D)Reinstall screw and washer onto the back of the control panel with a Phillips screwdriver..

E)Replace burner control knobs..

REFILLING THE LIQUID PROPANE CYLINDER

We recommend that you refill the LP cylinder before it is completely empty.. Removal of the LP cylinder:

A)Close cylinder valve (turn clockwise) (1)..

B)Unscrew regulator coupling by turning counterclockwise, by hand only (2)..

C)Lift cylinder out of cabinet..

To fill, take the LP cylinder to a gas propane dealer, or look up “gas-propane” in the phone book for other sources of LP gas..

mWARNING: We recommend that your LP cylinder be filled at an authorized LP gas dealer, by a qualified attendant, who fills the cylinder by weight. IMPROPER FILLING IS DANGEROUS.

mCAUTION: Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

1

2

3

6

12

4

5

12

Page 12
Image 12
Weber 89962 manual Refilling the Liquid Propane Cylinder, Check, Reinstall Control Panel