GAS INSTRUCTIONS

Remove Control Knobs & Control Panel For Leak Testing

1

2

You will need: Phillips screwdriver..

 

 

A) Take off the burner control knobs (1)..

 

 

B) Remove screw and washer from back of control panel with a Phillips screwdriver (2)..

 

 

C)

Remove machine screw from lower left and right side of control panel with a Phillips

 

 

 

screwdriver (3)..

3

 

D)

Tilt the back edge of the control panel up.. Carefully lift control panel up and away

 

 

 

 

from frame (4)..

 

 

E) Disconnect the igniter wires from the ignition module (5)..

 

 

F)

Replace control panel when leak check is completed..

 

 

4

CHECK FOR GAS LEAKS

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, which can cause serious bodily injury or death and damage to property.

Note: All factory-made connections have been thoroughly checked for gas leaks.The burners have been flame-tested.As a safety precaution however, you should recheck all fittings for leaks before using your Weber® gas barbecue. Shipping and handling may loosen or damage a gas fitting.

mWARNING: The gas connections of your gas grill have been factory tested. We do however recommend that you leak check all gas connections before operating your gas grill.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

If your grill has a side burner make sure the side burner is turned off..

Turn on gas supply at source..

mWARNING: Do not ignite burners when leak checking.

You will need: A soap and water solution and a rag or brush to apply it..

A)Mix soap and water..

B)Turn on gas supply (1)..

C)Check for leaks by wetting the fitting with the soap and water solution and watching for bubbles.. If bubbles form, or if a bubble grows, there is a leak..

If there is a leak, turn off the gas and tighten the fitting. Turn the gas back on and recheck with the soap and water solution. If leak does not stop do not use the barbecue. Contact the customer service representative in your area using the contact information on our web site. Log onto www.weber.com®.

D)When leak checking is complete, turn gas supply off at the source and rinse connections with water..

Note: Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.