Fisher & Paykel CG604D, CG451D, CG603D Clearance Dimensions, D F G H, Clearance dimensions mm

Models: CG302D CG752D CG903D CG905D CG603D CG451D CG604D

1 16
Download 16 pages 41.91 Kb
Page 7
Image 7
5 CLEARANCE DIMENSIONS

5 CLEARANCE DIMENSIONS

7

 

I

E

A D

Clearance dimensions (mm)C

B

D

F

G

H

ISO

Clearance dimensions (mm)

FRONT

CG302D

CG451D

CG603D

CG604D

CG752D

CG903D

CG905D

A

minimum clearance from left edge of cutout to nearest combustible surface

120

60

115

130

115

115

130

B

minimum clearance from right edge of cutout to nearest combustible surface

120

60

115

115

115

115

115

C

minimum clearance from rear edge of cutout to:

 

 

 

 

 

 

 

nearest combustible surface

160

85

160

160

125

125

160

 

nearest non-combustible surface

45

45

45

45

45

45

45

D

minimum height of non-combustible material when used on adjacent walls

150

150

150

150

150

150

150

 

minimum clearance from glass surface to:

 

 

 

 

 

 

 

E

rangehood

650

650

650

650

650

650

650

any other overhead exhaust fan

800

800

800

800

800

800

800

 

downward facing combustible surface

650

650

650

650

650

650

650

 

downwards-facing tiled or fire resistant surface

500

500

500

500

500

500

500

F

minimum clearance below top of benchtop to:

 

 

 

 

 

 

 

combustible surface

70

70

70

70

70

70

70

 

Fisher & Paykel oven or nearest non-combustible surface

65

65

65

65

65

65

65

G

minimum distance from right edge of cooktop to gas connection point on wall

250

250

250

250

250

250

250

(if using a flexible hose)

 

 

 

 

 

 

 

 

H

distance from floor to gas connection point on wall (if using a flexible hose)

min. 800 -

min. 800 -

min. 800 -

min. 800 -

min. 800 -

min. 800 -

min. 800 -

max. 850

max. 850

max. 850

max. 850

max. 850

max. 850

max. 850

 

 

I

maximum overall depth of overhead cabinetry

600

600

600

600

600

600

600

Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of the product, on the right-hand side. It should be accessible with the product installed.

Page 7
Image 7
Fisher & Paykel CG604D, CG451D, CG603D, CG905D, CG903D, CG752D, CG302D Clearance Dimensions, D F G H, Clearance dimensions mm