Flame failure safety feature

JET MODELS (CG602 & CG902 Series)

Flame failure safety feature

Some cooktops have a flame failure safety thermocouple fitted (see previous diagram).

When lighting the burner on flame failure models, hold the knob down for five seconds after the burner has lit.

Releasing the burner knob too soon will extinguish the flame.

In the event of the burner flame being accidentally blown out, the flame failure safety device will cut off the gas supply. Before relighting the burner, turn the knob off and wait one minute.

Power failure

In the event of a power failure, the burners can be lit by holding a match close to the side of the burner and turning the control knob to the high flame Manual background position. Wait until the flame is burning all the way around the burner cap before adjusting.