3-wire connections

For use where local codes permit grounding through the Neutral wire.

Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 18.

1.Remove the terminal block cover plate.

2.Insert the power cord with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete.

Note: a strain relief must be used.

2

strain relief clamp sections

strain relief screws

3.Loosen or remove the center terminal block screw. Connect the neutral wire (center) of the power supply cord to the center terminal screw of the terminal block. Tighten screw.

4.Connect the other wires to the upper and lower terminal block screws marked with the letter L. Tighten screws.

Note: If the appliance is moved back to a 3-wire installation the ground link must be refitted.

4

3

4

5.Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer. Secure cover with securing screw.

6.Tighten strain relief screws.

5

6

20