4-wire connections

Use approved 4-wire Power Supply Cord or a 4-wire Cable for Direct Wiring as described on page 18.

1.Remove the terminal block cover plate.

2.Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete.

Note: a strain relief must be used.

2

strain relief clamp sections

strain relief screws

3.Remove center terminal block screw.

4.Remove appliance ground link by removing the ground connector screw (green screw).

3

4

Note: If the appliance is moved back to a 3-wire installation the ground link must be refitted.

5.Connect ground wire (green) of the power supply cord to the ground conductor green screw. Tighten screw.

6.Connect the neutral wire (white) of the power supply cord to the center terminal screw of the terminal block. Tighten screw.

7.Connect the red wire and black wire to the upper and lower terminal block screws marked with the letter L. Tighten screws.

7

6 5

7

8.Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure cover with securing screw.

9.Tighten Strain Relief screws.

8

9

 