Siemens HE2528U, C), HE2224(U, HE2425(U Three Wire Flexible Conduit Con- nection

Models: HE2224(U HE2528U C) HE2425(U

1 56
Download 56 pages 19.88 Kb
Page 16
Image 16
Three Wire Flexible Conduit Con- nection

Installation

16.Properly secure flexible conduit at knockout on angle and at supply side junc- tion box. The wiring is now complete.

Three Wire Flexible Conduit Con- nection

green

groundblack wire screw

red wire

white wire

green ground wire

Figure 17: Completed Four Wire Flexible Conduit Connection

Note:

DO NOT plug in range at this time.

The Four Wire Connection is preferred, but where local codes and ordinances permit grounding through neutral and/or conversion to four wire is impractical, unit may be connected to the power supply via a three wire connection.

1.Disconnect electrical power at the breaker box.

2.Remove the terminal block cover to expose the terminal block.

Figure 3: Terminal Block

4. Remove the TOP nut, star washer, and round washer from each post.

Note:

DO NOT remove last round washer, last nut or internal wire leads.

5.Place one terminal lug (packaged with this manual) on each post. Replace the star washer and round washer and secure with 20 inch pounds of torque.

6.Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.

3/8 “

Figure 7: Wire Stripping

English 12

Page 16
Image 16
Siemens HE2528U, C), HE2224(U Three Wire Flexible Conduit Con- nection, Completed Four Wire Flexible Conduit Connection