6.Remove ground strap from CENTER post, rotate so that wide end is at TOP and attach wide end to range through hole below junction box. Attach GREEN wire on TOP of ground strap. Tighten Screw.
green ground screw
ground wire
ground strap
Figure 7: Four Wire Range Cord Connection - Ground Strap and Wire
8.Attach RED wire, round washer, star washer and nut IN THIS ORDER to LEFT post.
9.Attach WHITE wire, round washer, star washer and nut IN THIS ORDER to CENTER post.
10.Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to RIGHT post.
red
black
white
Figure 11: Four Wire Range Cord Connection (continued)
12.Tighten all connections securely and replace terminal block cover.
13.Properly secure strain relief. See “Install Strain Relief” on page 6.
Note:
DO NOT plug in range at this time.
Three Wire Range Cord Connection The Four Wire Connection (above) is preferred, but where local codes and ordi- nances permit grounding through neutral and where conversion to four wire is impractical, the unit may be connected to the power supply via a three wire con- nection.
1. Disconnect electrical power at breaker box.