Fisher & Paykel OR120 Installation instructions, To connect the gas supply

Models: OR120

1 48
Download 48 pages 15.45 Kb
Page 13
Image 13
To connect the gas supply:

Installation instructions

11

Notes:

Flexible hoses can be used where the sited ambient temperature of the hose does not exceed 70°C. These hoses must be manufactured in accordance with BS669 part 1 and be of the correct construction for the type of gas being used.

Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses can be identified by a either a red band or stripe on the rubber outer coating of the hose).

The hose should not be crushed or trapped or be in contact with sharp or abrasive edges. It should also not be subjected to corrosion by acidic cleansing agents.

To connect the gas supply:

1Fit the 1/2” BSP (female) connector (supplied with the cooker in a separate kit) to the gas inlet at the rear of the cooker interposing the gasket. Check the correct positioning of the connector as shown and always use two suitable spanners (Fig 6b).

2Connect the gas supply to the gas inlet at the rear of the cooker. If the pipe has to cross the cooker, it must be positioned under the protected area of the cooker (see Fig 6a)

3 To avoid damage to the appliance gas rail inlet pipe tighten the fittings using two suitable spanners (Fig. 6b).

4 Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then recheck for leaks.

IMPORTANT!

Fig. 6a

Do not use a naked flame to test for leaks.

Cooker manifold

Manifold male Do not use a naked flame to test for leaks. pipe fitting Manual backgroundManual background

1/2” G cylindrical (ISO 228-1) male

Gasket (*)

1/2” G cylindrical (ISO 228-1) female

Connector (*)

1/2” BSP (female)

(*) Supplied with the appliance in a separate kit.

 

 

 

10 mm

 

20 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 mm

 

 

 

 

 

10 mm

 

 

 

 

 

 

 

 

 