Fisher & Paykel OR120 Maintenance instructions, Replacing the burner injectors

Models: OR120

1 48
Download 48 pages 15.45 Kb
Page 15
Image 15
Maintenance instructions 13

Semi-rapid

 

burner

J

 

Fig. 8a

Triple ring wok burner

J

Fig. 8b

Maintenance instructions 13

Replacing the burner injectors

If the injectors are not supplied, contact the Fisher & Paykel Authorised Service Centre.

Select the injectors to be replaced according to the ‘Table for the choice of injectors’.

To replace the injectors:

Remove pan supports and burners from the cooktop.

Using a wrench, substitute the nozzle injectors “J” (figs. 8a - 8b - 8c) with those most suitable for the kind of gas used.

The burners are designed so that adjustment of primary air is not required.

Dual burner

J

Injector for inner crown

J

Injectors for outer crowns

Fig. 8c

Page 15
Image 15
Fisher & Paykel OR120 installation instructions Maintenance instructions, Replacing the burner injectors