Converting to a different gas type

This appliance is suitable for use with Natural gas or LPG (check the “gas type” sticker attached to the appliance). To convert from one gas type to another, you need to replace the injectors, and then adjust the minimum burning setting.

Replacing the injectors

1Remove the trivets and burners from the cooktop.

2Using a spanner, remove the injector (shown in Figs. 25-26 following) and replace it with one according to the gas type (see the ‘Table for the choice of injectors’).

3Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the gas inlet connections. This label states that the gas cooktop has been converted for use with LPG/ Natural gas.

Adjusting the minimum burner setting

4Follow the instructions on Page 21, ‘Adjusting the minimum burner setting’.

Important!

If you are converting the cooker from Natural gas to LPG,remove the gas pressure regulator before connecting the cooker to the gas supply and replace with the test point adaptor supplied with the conversion kit.

If you are converting the cooker from LPG to Natural gas, remove the test point adaptor before connecting the cooker to the gas supply and replace with the gas pressure regulator supplied with the conversion kit.

Notes:

- The burners are designed so that regulation of primary air is not required.

Injector

Injector

Fig. 25 Auxiliary, rapid and semi-rapid burners

Fig. 26 Triple-ring wok burner