Installation instructions

Ventilation requirements (GB & IE only)

The appliance should be installed into a room or space with an air supply in accordance with BS 5440-2:2000.

For rooms with a volume of less than 5 m3 - permanent ventilation of 100 mm2 free area will be required.

For rooms with a volume of between 5 m3 and 10 m3 a permanent ventilation of 50 cm2 free area will be required unless the room has a door which opens directly to the outside air in which case no permanent ventilation is required.

For rooms with a volume greater than 10 m3 - no permanent ventilation is required.

Important!

Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent.

Where there are other fuel burning appliances in the same room, BS 5440-2:2000 should be consulted to determine the correct amount of free area ventilation requirements.

Gas installation (GB & IE only)

Important!

This cooker uses NATURAL GAS only and cannot be used on any other gas without modification. This appliance is manufactured for conversion to LPG if required. If the injectors are not supplied they can be obtained from the After-Sales Service.

Installation & service regulations

It is a legal requirement that all gas appliances are Installed & Serviced by a competent person in accordance with the current editions of the following Standards & Regulations or those regulations appropriate to the geographical region in which they are to be installed:

Gas Safety (Installation & Use) Regulations Building Regulations

British Standards

Regulations for Electrical Installation

Installation and service of any gas product must be made by a suitably qualified person competent on the type of product being installed or serviced and holding a valid certificate of competence for the work being carried out. Currently the proof of competence is the Accredited Certification Scheme (ACS) or S/NVQ that has been aligned to the ACS. It is also a requirement that all businesses or self employed installers are members of a class of person approved by the Health and Safety Executive. Currently the only body with such approval is CORGI.

Gas connection

The installation of the cooker to Natural Gas or LP Gas must be carried out by a qualified gas engineer. Installers shall take due account of the provisions of the relevant British Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.

Note: It is recommended that the gas connection to the cooker is installed with a flexible connecting tube made to BS 5386.

Page 12
Image 12
Fisher & Paykel OR90 Ventilation requirements GB & IE only, Gas installation GB & IE only, Gas connection

OR90 specifications

Fisher & Paykel has long been synonymous with innovation in the kitchen appliance sector, and the OR90 is a testament to this legacy. This multifunctional oven is designed not only to meet the diverse needs of modern cooking but also to elevate the culinary experience for home chefs.

One of the standout features of the Fisher & Paykel OR90 is its generous capacity. With a spacious interior, this oven allows users to cook larger portions or multiple dishes at once, making it ideal for family gatherings and entertaining. The design incorporates a sleek, modern aesthetic that seamlessly integrates with a variety of kitchen layouts, enhancing both functionality and visual appeal.

The OR90 is built with several advanced technologies that set it apart from traditional ovens. One of its key features is the self-cleaning function, which employs a pyrolytic cleaning system. This innovative method heats the oven to a high temperature, effectively incinerating any food residue, which allows for easy cleanup and maintenance.

The appliance also offers multiple cooking modes, providing versatility for different culinary techniques. Among these modes are bake, roast, grill, and fan bake, enabling users to achieve the perfect cooking results for any dish. The fan bake option circulates hot air evenly, ensuring consistent cooking temperatures, which is essential for achieving restaurant-quality results at home.

Additionally, the OR90 is equipped with advanced safety features. It includes a cool-to-touch door, which minimizes the risk of burns, making it a safe choice for families. Furthermore, the oven has a built-in temperature probe, allowing home chefs to monitor the internal temperature of meats and ensure they are cooked to perfection without constant checking.

Convenience is also at the forefront of the design, as the OR90 features intuitive controls and a user-friendly interface. The clear display offers easy navigation through the various settings, making it accessible for cooks of all skill levels.

In summary, the Fisher & Paykel OR90 is an excellent choice for those seeking a high-performance oven that combines innovative technology with user-friendly features. Its spacious capacity, self-cleaning capabilities, various cooking modes, and safety systems make it a valuable addition to any kitchen, empowering home chefs to explore their culinary creativity with confidence.