Warranty
Flowtron warrants your Galaxie PowerVac to be free from defects in materials or workmanship under normal use and service for one year from date of original purchase. All parts with exception of burned out bulbs will be repaired or replaced free of charge. Any implied warranties, including the implied warranty of merchantability are also limited in duration to the one year period from the original purchase date.
The provisions of this warranty shall not apply to any product which as been subject to misuse, neglect or accident, nor which is used for a purpose for which it is not designed, or which shall have been repaired or altered in any way so as to adversely affect its performance and reliability. Service by unauthorized parties voids your warranty. Warranty covers only the original purchaser.
Flowtron neither assumes nor authorizes any person to assume for it any other liability in connection with its product. No responsibility is assumed for any consequential damages that may result from the use of a Flowtron product, nor for damages due to accident, abuse, lack of responsible care, the affixing of any unauthorized attachments, loss of parts or subject- ing this unit to any but the specified voltage.
If the unit fails to operate during the warranty period, send the product, along with purchase receipt showing purchase date and description of the problem to: Flowtron Service Center, 15 Highland Avenue, Malden, MA 02148. Transportation costs for returning any defective product are the responsibility of the consumer.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Flowtron Outdoor Products, 15 Highland Ave., Malden MA 02148
1 - 800 - 343 - 3280
PV-440 Trouble Shooting Chart
|
|
|
|
|
|
|
|
|
|
|
|
| Symptom |
|
|
| Probable Cause |
|
|
| Remedy | ||
| Ultraviolet bulb, fan and |
|
|
| 1 . No power at outlet. |
|
| 1 | . Check for | ||
| colored LED’s do not |
|
|
| 2 . Hood interlock switch not closed. |
|
| 2 | . Check for proper latching of hood. | ||
| function . |
|
|
|
|
| |||||
|
|
|
|
|
| 3 . Unit not properly connected to its |
|
| 3 | . Check plug connections between unit and power pack low | |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| power pack. |
|
|
| voltage wire. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The fan does not run. |
|
| 1 . Fan clogged with insect debris. | 1 | . Clean fan. (See “Maintenance” section of owner’s manual). | |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| 1. Funnel end is not over collection tray |
| 1. Engage the funnel end with the collection tray nozzle opening. | |||
| No dead insects or insect |
|
|
| |||||||
| debris in collection tray. |
|
|
|
| nozzle opening. |
|
|
|
| |
|
|
|
|
|
| 2. Fan and/or funnel clogged with insect debris. |
| 2 | . Clean fan and funnel. (See “Maintenance” section of owner’s manual). | ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 1. Current mosquito population not readily |
| 1. Notably the day flying Asian tiger Mosquito. Operate the unit with the | |||
| Not catching mosquitoes. |
|
|
| attracted to the PowerVac. |
| |||||
|
|
|
|
|
| 2. Trap is not located in a productive site. |
|
| Octenol cartridge removed. | ||
|
|
|
|
|
|
| 2 | . Move trap to a new site. (See “Placement” section of owner’s manual). | |||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
Any problems you encounter that are not corrected by the action recommended in the trouble shooting chart should be referred to the
Flowtron Service Department,
Accessories
Accessories are available at your local retail outlet or by ordering
www.flowtron.com
Mosquito Attractant: – MA 1000 Slow release Octenol Cartridge
makes your Galaxie PowerVac more effective in attracting mosquitoes and biting flies .
Extension Cord – EC-50
50 foot low voltage extension cord. Allows placement of the Galaxie PowerVac an additional 50 feet away from the power source.
Mosquito Attractant Six Pack: – MA 1000-6
Flowtron Outdoor Products, 15 Highland Ave, Malden, MA 02148
Page 4