Testing Diodes

Good Diode

 

 

 

Good Diode

 

 

 

 

 

 

Single Beep

Forward Bias

Reverse Bias

Bad Diode

Bad Diode

Measuring AC or DC CurrentW(Models 111 and 112)

Warning

To avoid personal injury or damage to the Meter:

Never attempt to make an in-circuit current measure-

ment when the open-circuit potential to earth is > 600 V.

Check the Meter's fuse before testing. (See “Testing the Fuse”)

Use the proper terminals, switch position, and range for your measurement.

Never place the probes in parallel with a circuit or component when the leads are plugged into the current terminals.

Turn power OFF, break circuit, insert Meter in series, turn power on.

A

A

 

 

 

 

and

aej08f.eps

Open

Shorted

aej07f.eps