INSTALLATION
Continued
We recommend that you install a sediment trap in supply line as shown in Figure 14, page
13.Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
CONNECTING equipment shutoff valve to heater control
Installation Items Needed
• Phillips screwdriver
Lower
Louver
Flexible Gas
Line
Figure 15 - Flexible Gas Line Location
•sealant (resistant to propane/LP gas, not provided)
1. Open lower louver (see Figure 15).
NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility fromthefireplace(seeFigure14). The flexible gas supply line connection to the equipment shutoff valve should be accessible.
2.Route flexible gas line, included, from fireplace control to equipment shutoff valve through side access holes in outer casing.
3.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve
(see Figure 16).
CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings
4.Check all gas connections for leaks. See Checking Gas Connections, below. Feed flexible gas line into fireplace. Make sure the entire flexible gas line is in fireplace.
To Control Valve
| Equipment | |
| Shutoff | |
| Valve | |
Flexible Gas Line |
| |
from Fireplace |
| |
Gas Regulator | Propane/LP | |
Provided With | ||
To External Regulator | ||
Fireplace | ||
Natural GAS | ||
| ||
| To Gas Supply |
Figure 16 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
CHECKING GAS CONNECTIONS
WARNING:Testallgaspiping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Applyanoncorrosiveleakdetection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
14 | www.fmiproducts.com |