INSTALLATION
Continued
8.Move temperature adjustment back and forth to insure the bimetal is free from re- strictions.
9.Replace cover onto base. (Upon installa- tion, thermostat must be allowed to sta- bilize at room temperature for a minimum of 30 minutes for proper operation).
10.Set temperature adjustment to desired setting. This thermostat has been elec- tronically calibrated at the factory. No adjustment or leveling is necessary.
Optional Wall SWITCH - GWMS2
WARNING: Read and follow installation instructions. Installation should be done by a qualified installer familiar with
WARNING: Do not connect this switch to any electrical source! Electrical shock and/or fire hazard will occur.
1.Remove jumper wire from control valve (see Figure 20, page 16).
2.Connect one terminal of 25 ft. wire to the
“TH” terminal on the control valve. Con- nect other terminal to the “THTP” terminal on control valve. See Figure 22.
3.Route the 25 ft. wire to a convenient loca- tion to mount your wall switch (no outside walls).
INSTALLING LOG SET AND SCREEN
1.Remove log packaging material and discard packaging. Gently place log over burner (see Figure 25). Do not allow log to contact flame. If flame contacts log, soot will be created.
2.Reattach screen by placing notches in screen frame over shoulder screws and pushing down.
Shoulder
Screw
Log
Screen
Figure 25 - Installing Log and Screen
WARNING: Do not connect the switch to a power source. Electrical shock and/or fire hazard will occur.
IMPORTANT: The wire may be shortened but must not be lengthened.
4.Connect one bare wire end to each of the terminals of the provided wall switch.
5.Install the wall switch and cover in the wall.