Operation Continued
• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4 through 8.
8.Slightly push in and turn control knob coun-
terclockwise to the ON position.
9.Set flame adjustment knob to any level between HI and LO.
10.To leave pilot lit and shut off burners only, turn control knob clockwise to PILOT posi- tion. If using optional
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Piezo | Flame | Control | |
Ignitor | |||
Adjustment | Knob | ||
Button | |||
Knob |
| ||
|
|
Figure 26 - Control Knob and Ignitor
Button Location (Shown as Supplied -
No Control Options)
Pilot
BurnerIgnitor
Electrode
Figure 27 - Propane/LP Gas Pilot
Pilot Burner | Ignitor |
| Electrode |
Figure 28 - Natural Gas Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1.Turn control knob clockwise to the OFF position.
2.If Using Optional
3.Close equipment shutoff valve (see Figure
17, page 15).
WARNING: Make sure remote sensor selector switch is in the OFF position when you are away from home for long periods of time.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Lighting Instructions, page 17.
2.Press control knob and light pilot with match.
3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow steps 8 and 9 under Lighting Instructions.
Optional GWMT1 Wall
mounted Thermostat
Set the temperature adjustment on wall thermostat to the desired setting. The thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.
Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper opera- tion. See installation instructions on pages 16 and 17.
Optional GWMS2 Wall
Mounted SWITCH
This wall switch works just like the conventional light switch. Flip switch up for on and down for off.
Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the fireplace being inadvertently turned on without the proper precautions being taken. See installation instructions on page 17.
www.fmiproducts.com | 19 |