TROUBLESHOOTING

PROPANE/LP VENT-FREE FIREPLACE SYSTEM

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor cable pinched or wet

1.

Free ignitor cable if pinched by any

spark at ODS/pilot

 

 

 

metal or tubing. Keep ignitor cable dry

 

2.

Ignitor electrode not connected to igni-

2.

Reconnect ignitor cable

 

 

tor cable

 

 

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode broken

5.

Replace pilot assembly

 

6.

Ignitor electrode positioned wrong

6.

Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Re- peat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly

7.Replace gas regulator

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Safety interlock system has been triggered

4.Equipment shutoff valve not fully open

5.Thermocouple connection loose at con- trol valve

6.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/pilot

7.Thermocouple damaged

8.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Wait one minute for safety interlock sys- tem to reset. Repeat ignition operation

4.Fully open equipment shutoff valve

5.Hand tighten until snug, then tighten 1/4 turn more

6.A) Contact local propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly

7.Replace pilot assembly

8.Replace control valve

www.desatech.com