OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
| |||
Burner does not light after ODS/pilot is lit | 1. | Burner orifice is clogged | 1. | Clean burner (see Cleaning and Mainte- | ||
|
|
|
|
| nance, page 19) or replace burner orifice | |
|
| 2. | Inlet gas pressure is too low | 2. | Contact local propane/LP gas company | |
|
|
|
|
|
|
|
Delayed ignition of burner | 1. | Manifold pressure is too low | 1. | Contact local propane/LP gas company | ||
|
| 2. | Burner orifice is clogged | 2. | Clean burner (see Cleaning and Mainte- | |
|
|
|
|
| nance, page 19) or replace burner orifice | |
|
|
|
|
|
|
|
Burner backfiring during combustion | 1. | Burner orifice is clogged or damaged | 1. | Clean burner (see Cleaning and Mainte- | ||
|
|
|
|
| nance, page 19) or replace burner orifice | |
|
| 2. | Burner damaged | 2. | Replace burner pressure | |
|
| 3. | Low inlet gas pressure | 3. | Contact local propane/LP gas company | |
|
| 4. | Gas regulator defective | 4. | Replace gas regulator | |
|
|
|
|
|
|
|
Yellow flame during burner combustion | 1. | Not enough air | 1. | Check burner for dirt and debris. If | ||
|
|
|
|
| found, clean burner (see Cleaning and | |
|
|
|
|
| Maintenance, page 19) | |
|
| 2. | Gas regulator defective | 2. | Replace gas regulator | |
|
|
|
|
|
|
|
Slight smoke or odor during initial operation | 1. | Residues from manufacturing processes | 1. | Problem will stop after a few hours of | ||
|
|
|
|
| operation | |
|
|
|
|
|
|
|
Fireplace produces a whistling noise when | 1. | Turning control knob to HI position | 1. | Turn control knob to LO position and | ||
burner is lit |
| when burner is cold |
| let warm up for a minute | ||
|
| 2. | Air in gas line | 2. | Operate burner until air is removed from | |
|
|
|
|
| line. Have gas line checked by local pro- | |
|
|
|
|
| pane/LP gas company | |
|
| 3. | Air passageways on fireplace blocked | 3. | Observe minimum installation clear- | |
|
|
|
|
| ances (see pages 8 through 10) | |
|
| 4. | Dirty or partially clogged burner orifice | 4. | Clean burner (see Cleaning and Mainte- | |
|
|
|
|
| nance, page 19) or replace burner orifice | |
|
|
|
|
|
|
|
White powder residue forming within burner box or on adjacent walls or furniture
1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. may turn into white powder residue
1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products
www.desatech.com | Continued |